19
11
Installation
11.1
Presses usable for pressing
The DiaSafe
®
anchoring systems were tested and approved by pressings produced by REMS radial
presses. The following models are suitable for pressing:
REMS Power-Press
REMS Power-Press SE
REMS Power-Press ACC
REMS Akku-Press
REMS Akku-Press ACC
These machines exert 36 kN pressing force which finally results in 100 kN force.
The manufacturer of the press must inspect all radial presses annually for appropriate operation. Make
sure that the used press has a certificate which verifies the inspection of the press within 12 months.
In addition to the above list, when using a different press, the use of presses with equivalent technical
specifications is required or they must be approved by the manufacturer of the DiaSafe
®
systems.
11.1.1
Pressing jaw and lining to be used for pressing
Pressing shall be performed with T12 press lining in any case, which fits in the standard pressing jaw.
T 12 press lining and pressing jaw
When using the press - with special attention to the lifetime of the pressing jaws and press linings - the
manufacturer
’
s specifications shall be observed. The T 12 press lining of the press was developed
specifically for the DiaSafe
®
Glide systems. This can be procured directly from the manufacturer of the
press or from the distributor or manufacturer of the DiaSafe
®
system.
All other installation information can be found in the product specific Installation Guide.
12
Disposal
Do not dispose of the fall protection system in the house waste. Following national requirements, gather
the used parts and dispose of them in an environmentally responsible fashion.