DSP-100 User Manual
Page 20 of 25
DSP100_MAN_A
.25 .5
1
2
4
8
.25 .5
1
2
4
8
.25 .5
1
2
4
8
.25 .5
1
2
4
8
0.00
Off Off Off Off Off Off
4.00
Off Off Off Off On Off
8.00
Off Off Off Off Off On
12.00
Off Off Off Off On On
0.25
On Off Off Off Off Off
4.25
On Off Off Off On Off
8.25
On Off Off Off Off On
12.25
On Off Off Off On On
0.50
Off On Off Off Off Off
4.50
Off On Off Off On Off
8.50
Off On Off Off Off On
12.50
Off On Off Off On On
0.75
On On Off Off Off Off
4.75
On On Off Off On Off
8.75
On On Off Off Off On
12.75
On On Off Off On On
1.00
Off Off On Off Off Off
5.00
Off Off On Off On Off
9.00
Off Off On Off Off On
13.00
Off Off On Off On On
1.25
On Off On Off Off Off
5.25
On Off On Off On Off
9.25
On Off On Off Off On
13.25
On Off On Off On On
1.50
Off On On Off Off Off
5.50
Off On On Off On Off
9.50
Off On On Off Off On
13.50
Off On On Off On On
1.75
On On On Off Off Off
5.75
On On On Off On Off
9.75
On On On Off Off On
13.75
On On On Off On On
2.00
Off Off Off On Off Off
6.00
Off Off Off On On Off
10.00
Off Off Off On Off On
14.00
Off Off Off On On On
2.25
On Off Off On Off Off
6.25
On Off Off On On Off
10.25
On Off Off On Off On
14.25
On Off Off On On On
2.50
Off On Off On Off Off
6.50
Off On Off On On Off
10.50
Off On Off On Off On
14.50
Off On Off On On On
2.75
On On Off On Off Off
6.75
On On Off On On Off
10.75
On On Off On Off On
14.75
On On Off On On On
3.00
Off Off On On Off Off
7.00
Off Off On On On Off
11.00
Off Off On On Off On
15.00
Off Off On On On On
3.25
On Off On On Off Off
7.25
On Off On On On Off
11.25
On Off On On Off On
15.25
On Off On On On On
3.50
Off On On On Off Off
7.50
Off On On On On Off
11.50
Off On On On Off On
15.50
Off On On On On On
3.75
On On On On Off Off
7.75
On On On On On Off
11.75
On On On On Off On
15.75
On On On On On On
Internal Settings
There are two jumpers on the inside of the detector case labelled J1 and J2. See figure below for location of these
jumpers.
Extend Only During Green (Jumper J1)
–
This jumper
modifies the extension feature. Normal operation always
honors any programmed extension time. By removing jumper
J1 inside the detector, and connecting the AC green input for
that phase to connector pin J (Delay Inhibit), the DSP-100 can
be set to extend only during the green interval. Any vehicle
exiting the detection area during the non-green intervals of the
associated phase will not activate the extension interval on the
detector. The detector is shipped from the factory with this
jumper installed.
Fail-Safe / Fail-Secure (Jumper J2)
–
This jumper selects
fail-safe or fail-secure operation. If the jumper is installed, as
in the figure below, the detector will behave in the fail-safe
mode. To have the detector behave in the fail-secure mode,
simply remove the J2 jumper. The detector is shipped from the
factory with this jumper installed (the fail-safe condition).
In general, a fail-safe detector will activate the output when the loop circuit is failed. This is useful on most calling
detectors, stop bar detectors, and safety loops. Fail-safe is used in applications where it is important to not have
an output active if the loop circuit has failed. The fail-secure mode is useful in counting detectors, speed detectors,
and high-security areas or installations where containment is needed.
Figure 12: Internal Jumper Locations