Vers. 1.8 (2010-10-15)
6 / 6
18-3002-00
Tab. 6 Elektrische Spezifikation Sensoranschluss AB2 |
Electrical specification sensor connector AB2
Pin
Spezifikation |
Specification
1 (OUT5)
Gegentakt |
Push-Pull
LOW: 0V; HIGH: +U
B
-1V; max. 100 mA
2 (OUT6)
Gegentakt |
Push-Pull
LOW: 0V; HIGH: +U
B
-1V; max. 100 mA
3 (OUT7)
Gegentakt |
Push-Pull
LOW: 0V; HIGH: +U
B
-1V; max. 100 mA
4 (OUT8)
Gegentakt |
Push-Pull
LOW: 0V; HIGH: +U
B
-1V; max. 100 mA
5 (OUT9)
Gegentakt |
Push-Pull
LOW: 0V; HIGH: +U
B
-1V; max. 100 mA
6 (OUT10)
Gegentakt |
Push-Pull
LOW: 0V; HIGH: +U
B
-1V; max. 100 mA
7 (OUT11)
Gegentakt |
Push-Pull
LOW: 0V; HIGH: +U
B
-1V; max. 100 mA
8 (OUT12)
Gegentakt |
Push-Pull
LOW: 0V; HIGH: +U
B
-1V; max. 100 mA
Tab. 7 RS232
Pin
Bedeutung |
Description
Spezifikation |
Specification
1 (GND)
GND
0 V
2 (TXD)
Senden |
Send
-5 V...+5 V
3 (RXD)
Empfangen |
Receive
-5 V...+5 V
4 (+Ub)
Optional Spannungsausgang |
Optional voltage output
18…28 VDC
Schirm |
Shield
Geräteschirmung (Erdung) |
Device shield (earth)
Erde |
Earth
Tab. 8 RS232 Parameter |
Parameters
Parameter
Wert |
Value
Baud rate
9.600...115.200
Data bits
8
Parity
no
Stop bits
1
Flow control
no
Hinweis |
Note
:
Die Voreinstellung für die Baud Rate der RS232 Schnittstelle beträgt 28800. |
The baud rate of the RS232 interface is pre-set to 28800.
Tab. 9 USB
Pin
Bedeutung |
Description
Spezifikation |
Specification
1 (GND)
GND (Schwarz |
black
)
0 V
2 (VBUS)
VBUS (Rot |
red
)
+5 V
3 (D-)
D- (Weiß |
white
)
-400 mV
4 (D+)
D+ (Grün |
green
)
+400 mV
Schirm |
Shield
Geräteschirmung (Erdung) |
Device shield (earth)
Erde |
Earth
Wichtiger Hinweis |
Important note
:
Es ist darauf zu achten, dass die Schirmleitungen der verwendeten Sensorschlussleitungen an Erde
angeschlossen werden! |