If connecting to an existing masonry
chimney
it is recommended that a flue forming pipe
(short length of flue pipe) is used and the void
between the flue forming pipe and the
chimney filled with vermiculite concrete.
A suitable access hole will need to be made in
the chimney breast to allow the back filling to
be carried out and then filled and sealed once
the installation is complete.
Alternatively a connection can be made using
a register plate although it will be necessary
to allow access for fitting the flue pipe to the
register plate and sealing all joints.
R
E
-A
SSEMBLING
T
HE
S
TOVE
1.
Refit the base fixing access plate and
gasket, Air Valve Cassette (with the air
controls set to maximum), firebricks,
brick baffle and log retainer.
2.
Wind the M6 Nuts to the ends of the
studs on the convection chamber
sides.
3.
Slide the Frame in to position and
tighten the nuts with a 10mm
spanner.