Specifications
Specifications
DC Voltage
(Auto-ranging)
Range
Resolution
Accuracy
400.0mV
0.1mV
±0.5% of rdg + 2 dgts
4.000V
1mV
40.00V
10mV
±1.2% of rdg + 2 dgts
400.0V
100mV
600V
1V
±1.5% of rdg + 2 dgts
Input Impedance:
7.8MΩ.
Maximum Input:
600V dc or 600V ac rms.
DC Current
(Auto-ranging for uA and mA)
Range
Resolution
Accuracy
400.0uA
0.1uA
±1.0% of rdg + 3 dgts
4000uA
1uA
40.00mA
10uA
±1.5% of rdg + 3 dgts
400.0mA
100uA
10A
10mA
±2.5% of rdg + 5 dgts
Overload Protection:
0.5A / 250V and 10A / 250V Fuse.
Maximum Input:
400mA dc or 400mA ac rms on uA / mA ranges, 10A dc or
ac rms on 10A range.
AC Voltage
(Auto-ranging except 400mV)
Range
Resolution
Accuracy
400.0mV
0.1mV
±
1.5%of rdg + 15 dgts
4.000V
1mV
±
1.2% of rdg + 3 dgts
40.00V
10mV
±
1.5% of rdg + 3 dgts
400.0V
100mV
600V
1V
±
2.0% of rdg + 4 dgts
Input Impedance:
7.8MΩ.
Frequency Range:
50 to 400Hz.
Maximum Input:
600V dc or 600V ac rms.
Summary of Contents for DL9205
Page 1: ...DL9205 AUTORANGING MULTIMETER operating manual EN 61010 1 CAT III 600V ...
Page 30: ...Notes ...
Page 31: ...Notes ...