background image

Safety Information

Features

•  High resolution to 1mA AC
• 3-2/3 digit (2400 count) LCD display
• White LED backlight
•  Built-in non-contact AC voltage detector  

plus torch

• Autoranging with auto power off
• 18mm Jaw opening

Summary of Contents for DL6506

Page 1: ...DL6506 MINI AC DC CLAMP ON METER operating manual EN 61010 1 CAT II 600V ...

Page 2: ...mplies with IEC536 class 11 Symbol of conformity confirms conformity with relevant EU directives The meter complies with EMC directives 89 336 EEC Specifically standards EN 50081 1 and EN 50082 1 as well as the Low Voltage Directive 73 23 EEC described in the standard EN 61010 1 The meter has been designed in accordance with the safety regulations for electronic measuring instruments EN 61010 1 IE...

Page 3: ...nsure that the rotary switch is set to the appropriate range Do not turn the rotary switch whilst making a measurement Use the appropriate terminals function and range for your measurements If the value to be measured is not known use the maximum measurement position and reduce the range step by step until a satisfactory reading is obtained Do not use or store the meter in an environment of high t...

Page 4: ...as the low battery indicator appears If the battery is low the meter may give false readings Turn the meter power off when not in use Remove the battery if the meter is in use for a long period Constantly check the battery as it may have leaked A leaking battery will damage the meter The meter may only be opened by a qualified service technician for calibration and repair ...

Page 5: ...Features High resolution to 1mA AC 3 2 3 digit 2400 count LCD display White LED backlight Built in non contact AC voltage detector plus torch Autoranging with auto power off 18mm Jaw opening ...

Page 6: ...al Battery Two 1 5V AAA batteries Low Battery indication BATT displayed on the LCD Auto OFF approx 7 minutes Operating conditions 32 F to 86 F 0 C to 30 C 90 RH 86 F to 104 F 30 C to 40 C 75 RH 104 F to 122 F 40 C to 50 C 45 RH Storage conditions 14 F to 140 F 30 C to 60 C 90 Relative Humidity Altitude Operate at less than 3000 meters Weight 175g including battery Dimensions 164 x 65 x 32mm Jaw op...

Page 7: ... Specifications Function Range Resolution Accuracy of reading DC Current 2A 1mA 2 8 10 digits 80A 100mA 3 0 8 digits AC Current 50 60Hz 2A 1mA 3 0 10 digits 80A 100mA 3 0 8 digits Non Contact AC Voltage 100VAC to 600VAC 50 60Hz 3 9 8 ...

Page 8: ...tton 3 Rotary function switch 4 Data HOLD and Backlight key 5 LCD display 6 Clamp trigger 7 One touch DCA ZERO key 8 Non contact AC voltage indicator light 9 Non contact AC voltage detector probe tip Function Maximum Inputs AC Current 80A DC Current 80A Input Limits ...

Page 9: ... range 2 Press the jaw trigger and clamp around fully enclosing a single conductor Do not allow a gap between the two halves of the jaw Refer to the diagram at right for the correct way to enclose a single conductor 3 Read the ACA value on the LCD wrong correct ...

Page 10: ... LIVE CIRCUIT TO VERIFY PROPER OPERARTION 1 Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet 2 If AC voltage is present the detector light will illuminate Note The conductors in electrical cord sets are often twisted For best results rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor Note The ...

Page 11: ...than 2 seconds to turn on the backlight This will also activate the Data Hold function To release the Data Hold function and return the meter to normal operation press the Data Hold key momentarily To turn off the backlight press and hold the Hold Backlight key for more than 2 seconds Auto Power Off The auto off feature will turn the meter off after 7 minutes Battery Replacement 1 When the low bat...

Page 12: ...e instrument has not been tampered with and returned to us unopened Damage due to dropping abuse or misuse is not covered by the warranty Outside the warranty period we offer a full repair and re calibration service Maintenance WARNING Do not attempt to repair or service you meter unless you are qualified to do so and have the relevant calibration performance test and service information To avoid ...