5. WIRING DIAGRAMS
A. Internal Connections
!
Head searchlight
J1
* CAUTION:
Ground is used as return pad when on the end-position switch. Always use the ground
comming from the control panel to avoid unwanted potential differences.
12
13
14
15
16
17
J1-6
J1-4/5
J1-7
-
Ground
+
Up
-
-
Ground
+
+
Ground
-
+
Ground
-
Pole
M
M2
J1-8
J1-4/5
J1-9
J1-8
J1-4/5
J1-9
-
-
Left
Right
J1-6
J1-4/5
J1-7
Motor 1
Down
Motor 2
-
M
M1
Terminal
24VDC (for PTC)
11
10
9
8
7
6
1
5
4
3
2
Motor left / right
6 - 13VDC
Motor Up / down
6 - 13VDC
Ground*
Microswitch V3 with roller lever, IP67 sealed
S1, S2, S3, S4
COB-LED 70W
LED driver
Terminal block 18 way
Motor 12VDC/6W, gearhead 1:370 (up / down)
Motor 12VDC/6W, gearhead 1:3700 (right / left)
PTC heater 12-24V 30W (self-regulating)
Description
Earth point
Head resisting cable 3 x1,5 - 1,25 m
Cable
Component
X1, X2
M2
M1
G1
D1
J1
PTC
S3
S4
Right
Left
X2
Drum
S2
X1
cable
PTC
S1
Mounting plate
motor house
G1
D1
Up
Down
Summary of Contents for 230RCB Series
Page 2: ...2 Version 1 1 January 2019 Den Haan Rotterdam Intentionally blank page ...
Page 10: ...10 Version 1 1 January 2019 Den Haan Rotterdam Intentionally blank page ...
Page 13: ...13 Version 1 1 January 2019 Den Haan Rotterdam 4 PHOTOS ...
Page 22: ...22 Version 1 1 January 2019 Den Haan Rotterdam 4 7 6 8 5 ...
Page 23: ...23 Version 1 1 January 2019 Den Haan Rotterdam Intentionally blank page ...