background image

6

Systems, 

L.L.C.

MS 

2000

MiniSteam Residential

Owner’s Manual

10. Hang the humidifier unit
carefully on the mounting bracket. 
(See Figure 9 at right)

11. Secure the bottom of the
humidifier unit to the wall using
the third screw. 
(See Figure 10 at right)

Figure 9

Figure 10

Summary of Contents for MiniSteam Residental SD 2000

Page 1: ...MS2000 Electronic Steam Humidifiers MiniSteam Residential Owner s Manual Read and Save these Instructions...

Page 2: ...als and workmanship in the course of normal and reasonable use for a period of 2 years from the date of installation or 2 years and 1 month from the date of shipment whichever comes first so long as t...

Page 3: ...ications Figure 2 1 Steam humidifier unit with blower attached 1 HC 101 humidistat 3 Screws and anchors 1 Fill connector IMPORTANT BEFORE beginning installation Check for shipping damage to cartons Ma...

Page 4: ...move the plastic steam cylinder by loosening the clamp on the top left of the cylinder and lifting the cylinder while twisting it up out of its base a Disconnect the wires on top by carefully loosenin...

Page 5: ...re the unit will hang level See Figure 4 at right CAUTION make sure that the screws will go into wall studs to support the weight of the humidifier 6 If the mounting screws will be screwed into wood d...

Page 6: ...r 12 IMPORTANT Maximum length of rubber steam hose is 20 feet 10 feet is supplied with the humidifier 5 9 Remove the mounting bracket from the back of the humidifier Mount the humidifier unit as close...

Page 7: ...Residential Owner s Manual 10 Hang the humidifier unit carefully on the mounting bracket See Figure 9 at right 11 Secure the bottom of the humidifier unit to the wall using the third screw See Figure...

Page 8: ...outlet nipple 12 Cut or drill a 2 1 2 hole in the side of the duct to fit the steam nozzle 13 Apply silicone caulk to the faceplate of the steam nozzle and insert it into the duct with the 5 16 outlet...

Page 9: ...eam hose There must be NO sags kinks or low areas in the steam hose that can collect condensate or otherwise restrict the steam flow Copper tubing may be used in place of the steam hose but it must be...

Page 10: ...17 at right 18 Reinstall the steam cylinder into the humidifier unit by pressing it down into the O ring fitting at the bottom and then securing all wires CAUTION Loose electrical connections could ca...

Page 11: ...water tubing to the compression fitting mounted in the plastic water fill fitting See Figure 20 at right 23 Attach the plastic fill fitting with the 1 4 OD copper tubing to the fill connection on the...

Page 12: ...he bottom of the humidifier unit and tighten the strain relief See Figure 23 at right 26 Insert the wires into the proper power wiring terminals and tighten all wires carefully CAUTION loose wires can...

Page 13: ...return duct only See Figure 25 above 27 Mounting the airflow switch Mount the airflow switch in the supply or return duct using the screws supplied Mount the device so that the diaphragm is in a verti...

Page 14: ...the strain relief connector around the wires 31 Connect the wires per one of the following control wiring diagrams directly to the bottom of the circuit board Figure 26 is the standard wiring diagram...

Page 15: ...valve and begin to fill with water Filling should stop when either the proper amperage is reached or the cylinder is full of water After a few minutes water should start to boil and steam should be pr...

Page 16: ...probes E Boiling will begin and steam will flow to the duct distributor pipes or to the Room Distribution Unit As water is boiled into steam the water level will reduce and so will the amperage draw...

Page 17: ...output of the humidifier for applications where the full output may not be needed 16 The MiniSteam Controller The controller parts are 1 RESET button to reset alarms When an alarm occurs the LEDs wil...

Page 18: ...t be needed 17 The Main Control Board 1 Connector for the front keypad 2 RESET button 3 DRAIN button for manual draining 4 UP button to increase capacity 5 Serial connection for smart homes 6 Amperage...

Page 19: ...ier with the On Off switch on the front and disconnect power to the unit at the external fused disconnect CAUTION If you have a blower unit there may be more than one disconnect 3 Loosen the hose clam...

Page 20: ...r with any object which may enlarge the orifice The flow regulator must meter water flow precisely or shortened cylinder life may result Remove the drain valve group and disassemble it Clean all parts...

Page 21: ...ater Faulty drainage Worn out cylinder ALARMS Lack of current High current Data error Faulty sensor EEPROM configuration error Power supply of controller FACE PAD LED 7 blinks LED 8 blinks LED 6 blink...

Page 22: ...mineral one or more electrodes has lost power amperage transformer broken contactor broken mineral bridge on electrode leaking fill valve drain valve obstructed loose bad wiring connection DIP switche...

Page 23: ...t the factory for an optional drain timer to force additional drains to control the minerals If you are using a softener check the salt being used If it contains any additives discontinue use flush al...

Page 24: ...Systems L L C MS2000 MiniSteam Residential Owner s Manual 23 Humidifier Wiring Diagram...

Page 25: ...mps Power Use 2 2 kW Water Pressure 15 100 psi Conductivity 125 1250 micromhos Shipping Weight RD103CL220 45 lbs RF103CL220 50 lbs Dimensional data 14 3 4 High X 11 Wide X 7 1 2 Deep Steam Nozzle High...

Page 26: ...hip in Humidification Systems L L C For more information call 1 800 DGH 4649 1834 Freedom Road Lancaster PA 17601 Tel 717 293 5210 Fax 717 293 0449 Internet http www dghsys com 1997 by DGH Systems L L...