Configuration

Settable parameters:

- Running pressure. 

When the pressure in the 
system falls below the Pm, 
PRESFLO

®

 starts-up the pump.

The Pm should always be 
higher by at least 0.2 – 0.3 
bar of the pressure genera-
ted by the column of water 
overlooking PRESFLO

®

.

The Pm value can be carried 
in the field between 1 bar and 
5 bar.

- Maximum current 
allowed.

PRESFLO

®

 is fitted with a cur-

rent sensor, which continually 
detects the absorption of the 
pump. If the current remains 
above the set Imax value for 
a significant period of time, 
PRESFLO

®

 stops the pump to 

protect it from damages (LOCK 
condition for OVERCURRENT).
PRESFLO

®

 nevertheless allows 

the Imax to be exceeded for 
short periods during the pump 
start-up phase.

For correct functioning, 
the Imax should be set at 
a value higher by approx. 
10 – 20% to the maximum 
absorption of the pump 

(normally indicated on the 
rating plate of the motor).

If this rating value is not known, 
it s better to leave the standard 
Imax value (16A) to avoid that 
the pump stops also in normal 
absorption conditions.

The Imax value may be varied 
in the field between 4A and 
16A.

Manufacturer’s setting:

PRESFLO

®

 is supplied with the 

following STANDARD CONFIGU-
RATION:
- Running pressure
   

Pm = 2 ( bar )

- Max. current allowed  
   

I max = 16 ( A )

Statement of Compliance: 

we declare, under our own respon-

sibility, that the product in question is in compliance with the fol-
lowing European Directives and national implementation provisions

2006/95/CEE  Low Voltage Directive
2002/95/CEE  (RoHS)
2002/96/CEE - 2003/108/CEE  (WEEE)
2004/108/CE  Electromagnetic Compa-
tibility Directive (EMC)
EN 60730-2-6
EN 61000 6-3

Bigarello 27.05.15

DGFLOW S.r.l.
President
Stefano Concini

Configuration

The adjustment of the starting 
pressure (Pm) and the ma-
ximum permissible current (I 
max) is done by means of two 
trimmers shown in FIG.

1. Remove the small screwdri-
ver and adjust the trimmer on 
the desired limits, according to 
the values shown on the plate 
located under the screwdriver.

2. The start-up pressure can 
be adjusted continuously from 
1 to 5 bar (trimmer A)

3. The maximum permissible 
current can be adjusted 
continuously from 4 to 12 A 
(trimmer B)

4. When you finish adjustment 
close the cover

CODE:
V / Hz:
I max: 

B

V00103101
~230 / 50-60
16

 A

SN 1506003

1

2

3

6

5

4

8

7

Exploded view of 
spare parts

Attention

: when orde-

ring spare parts, always 
state the position n° 
from the diagram below 
and the product code 
number found in the 
pressure-flow regulator 
technical data table.

Article

Version

Dimensions

= Off

= Flashing

= On

1 - Circuit board cover
2 - Sensor kit
3 - Circuit board
4 - Valve kit
5 - Two-pieces joint with OR
6 - Cable bushings
7 - Accumulator adapter
8 - Water accumulator

Problems

Signals

Possible causes

Solutions

PRESFLO

®

 

will not turn on

No power

Check the electrical connections

The pump will 
not start when 
a tap is turned on

PRESFLO

®

 model with an inadequate 

start-up pressure (Pm) for the chosen 
application.

Relocate PRESFLO

®

 to another position

Install a model with a higher start-up pressure (Pm)

Faulty electrical connections or 
pump out of service

Check the electrical connections and that the pump 
is working

PRESFLO

®

 “STAND-BY”

Reset PRESFLO

®

  (See Operation, point 3). 

PRESFLO

®

 in temporary shut down 

due to “DRY RUNNING” due to lack 
of water

Wait for the automatic restart or press START to 
restart manually (See Operation, point 4a)

Maximum pump pressure is 
insufficient

Replace the pump with one with more suitable 
characteristics

Install a model with a lower start-up pressure (Pm)

PRESFLO

®

 in temporary shut down 

due to “FREQUENT START-UP”

Wait for the automatic restart or press START to 
restart manually (See Operation, point 4b). Remove 
any cause of leakage from system or install an 
expansion tank

PRESFLO

®

 stops due to “OVERCUR-

RENT”

Check if the setting of the maximum current (Imax) 
is congruent with the data of the pumps’ rating 
plate. If after manually restarting the pump after 
correctly setting PRESFLO

®

, it again signals an 

anomaly, check that the motor has no mechanical 
or electrical problems.

The pump 
delivers no or low 
pressure

Filters or pipes may be partly blocked Check the water pipes

PRESFLO

®

’s valve will not open 

completely

Check that the valve is not blocked by any foreign 
objects and clean if necessary

The pump stops 
and starts 
repeatedly

Leaks within the system (less than 
the shut-off flow rate Qa)

Check the hydraulic connections and repair any 
leaks. If a leak cannot be repaired, install an 
expansion tank

The pump will 
not stop

The flow rate is higher than the 
shut-off flow rate (Qa)

Make sure that all taps are turned off and that 
there are no leaks within the system

PRESFLO

®

’s check valve will not 

close or is damaged

Check that the valve is not blocked by any foreign 
objects and clean if necessary

Summary of Contents for PRESFLO MULTI

Page 1: ...nic components PRESFLO can only be used with single phase pumps Working area Flow rate Pressure Shut off flow rate Start up pressure Qa Pm Safety regulations Before installing or using PRESFLO read this manual carefully and thoroughly The pump should be installed and serviced by qualified per sonnel responsible for making the hydraulic and electrical connections in compliance with the relevant reg...

Page 2: ...It occurs when there is no water After 15 seconds PRESFLO stops the pump and indicates an ERROR message PRESFLO AUTOMATICALLY tries to resume NORMAL SERVICE at intervals of increasing time 1 15 30 60 minutes and successively once every hour 24 H for AU NZ If PRESFLO detects any pressure and or flow NORMAL SERVICE is resumed otherwise the pump is stopped again until the next attempt is made A MANUA...

Page 3: ... turned on PRESFLO detects a flow the assembly pressure is normally higher than the START UP pressure but it may also be lower Press briefly or hold down the pump is stopped and put OUT OF SERVICE For instruc tions on how to reactivate the pump see point 3 The taps are turned off Sif there is no flow for a few seconds the pump is stopped NORMAL SERVICE the pump is running PRESFLO has detected that...

Page 4: ...be adjusted continuously from 4 to 12 A trimmer B 4 When you finish adjustment close the cover CODE V Hz I max B V00103101 230 50 60 16 A SN 1506003 1 2 3 6 5 4 8 7 Exploded view of spare parts Attention when orde ring spare parts always state the position n from the diagram below and the product code number found in the pressure flow regulator technical data table Article Version Dimensions Off F...

Reviews: