![DGF Fabrications Renaissance 16](http://html.mh-extra.com/html/dgf-fabrications/renaissance-16/renaissance-16_user-installation-and-servicing-instructions_2491663005.webp)
NJL/GTECH- 3/10/06 Revision No.3
4
HEAT INPUT/INJECTOR MARKINGS/BURNER PRESSURE SETTINGS
:
Model
Gross heat
input kW
Natural gas
injector:
Natural gas
setting
pressure
(mbar):
LPG gas
injector:
LPG gas setting
pressure (mbar):
Max
Min
Marking
Max
Min Marking
Max
Min
16”
7.0
3.5
510
15.0
4.0
220
33.0
9.0
16" (N.V.)
6.75
2.5
460
16.0
2.5
190
30.2
4.6
16" (Class II
Multi-flue)
5.5
3.0
460
10.7
3.4
16" (Class II
Multi-flue)
6.8
3.2
190
30.7
7.6
18”
8.8
4.5
650
13.0
4.0
240
32.0
8.0
22"
10.5
5.5
700 *
18.0
5.0
340
30.0
8.5
INJECTORS :
All injectors are marked (on the side of the body) as table above.
Note:
Injector marked 700 * is manufactured by Stereomatic; all other injectors are Bray Cat 82
type.
MAIN GAS CONNECTION :
8mm O.D. X M14 compression nut on R.H. side of gas control.
Anglo Nordic type:
APPLIANCE SERIAL NO. LOCATION :
Data plate affixed under burner assembly on appliance base
.
SPECIFIC REQUIREMENTS :
The fire must be installed in either
a) A specially prepared non-combustible builders opening with a chimney free from
obstruction and conforming to Fig no. 2.
Or
b) A non-combustible fire resistant fireplace with chimney free from obstruction and
conforming to the current Building Regulations. Make good as appropriate to leave and
opening with dimensions conforming to Fig no. 2. This may mean that the fire back (or
chair brick) will have to be removed.
They must NOT be mounted on a combustible floor or carpet
The fireplace or builders opening should only have two openings, an entrance through the
fireplace for the appliance, and an exit for the flue gas, all other openings must be sealed off.
A flue test in accordance with national regulations must be carried out to prove that there is a
positive up draught.
In the case of a Class I installation the chimney must be swept prior to installation.
The base of the builders opening must be flat, level and square with the fireplace.