26
Factory Testing Jumpers
The following jumpers are for factory testing only and should always be
set to their default configurations. Reconfiguring these jumpers will
cause problems with your system board.
JP1:
Off
JP17:
1-2 On
JP11:
1-2 On
JP24:
Off
JP12:
1-2 On
JP25:
1-2 On
JP14:
1-2 On
Jumper Settings for Lithium Battery
Jumper JC1
Lithium Battery
The G486VPC system board comes with a lithium battery. The default
setting of JC1 is 1-2 On for battery conservation during shipment of the
board. Before installing the system board onto your system unit, set JC1
to 2-3 On to use the lithium battery.
1-2 On: Default
3
2
1
2-3 On: Lithium battery
3
2