DeZurik D10350 Quick Start Manual Download Page 5

DeZURIK

May 2014 

Page 5 

D10350 

 
Mechanical Switches

 

(Continued)

 

Each switch is actuated by a rotating cam. To adjust a top switch, push the top cam down, rotate it to 
the desired position, and release the cam so it engages into the new position on the spline. To adjust a 
bottom switch, repeat the process with the bottom cam, but lift the cam upwards to rotate it to the 
desired position. Each cam may be further fine-tuned between spline positions by turning the set screw 
on the cam with a 1/16" hex driver. The set screw is limited to adjustment of no more than one full turn. 

Proximity Switches 

The two SPDT proximity switches each has a rating of 0.3 amp at 120 VAC, or 0.2 amp at 30 VDC. The 
switch contacts are sealed for low-energy switching of solid-state signal circuits. 

The top switch is factory set to trip as the valve reaches the closed or clockwise position, and the 
bottom switch is factory set to trip as the valve reaches the open or counterclockwise position. The 
internal wiring from the switches to the terminal strip is shown in Figure 2. 

Each switch is actuated as the white stripe on its rotating cam aligns with the white stripe on the switch. 
To adjust the top switch, push the top cam down, rotate it to the desired position, and release the cam 
so it slides into the new position on the spline. To adjust the bottom switch, repeat the process with the 
bottom cam, but lift the cam upwards to rotate it to the desired position. 

 

 

 

Figure 2

—Proximity Switches 

 

Summary of Contents for D10350

Page 1: ...DeZURIK Inc Sartell Minnesota USA Phone 320 259 2000 www dezurik com info dezurik com DEZURIK SWITCH AND POSITIONER TRANSMITTER Instruction D10350 May 2014...

Page 2: ...us pipeline materials Handle valves which have been removed from service with suitable protection for any potential pipeline material in the valve Inspection Your Switch and Position Transmitter has b...

Page 3: ...2014 Page 3 D10350 Table of Contents Description 4 Electrical Connections 4 Mechanical Switches 4 Proximity Switches 5 Position Transmitter 6 Indicator Adjustment 7 Switch Mounting Kit used on PMV Po...

Page 4: ...cribed in the following sections One pipe plug is provided with the unit If the connection is not used install the pipe plug tightly in the connection Do not use thread sealant Mechanical Switches The...

Page 5: ...rating of 0 3 amp at 120 VAC or 0 2 amp at 30 VDC The switch contacts are sealed for low energy switching of solid state signal circuits The top switch is factory set to trip as the valve reaches the...

Page 6: ...4 mA output Do not connect power until step 4 If the valve is in the closed or clockwise position connect an ohmmeter to terminals 2 and 3 of the potentiometer if the valve is in the open or countercl...

Page 7: ...in the indicator drum A4 The shaft adaptor may be a different size and or shape than shown in Figure 3 4 Rotate the indicator drum A4 to the desired position and push the shaft adaptor A1 and spacer...

Page 8: ...DeZURIK D10350 Page 8 May 2014 Switch Mounting Kit used on PMV Positioner Figure 5 Switch Mounting Kit used on PMV Positioner...

Page 9: ...l be the only effective guarantee or warranty binding on Seller despite anything to the contrary contained in the purchase order or represented by any agent or employee of Seller in writing or otherwi...

Reviews: