DEZEGA
DEZEGA EmSCAPE
9
Hood 1 has reflective element 2, window 3, half-mask 4. With elastic
straps of the hood, that require no adjustment, half-mask 4 tightly fits
human face. Obturator at the bottom of the hood prevents the suction
of toxic substances under the hood.
Gas mixture in the breathing system of the escape hood circulates
within the pendulum scheme of flow.
During exhale breathing mixture goes through half-mask 4, then
through breathing tube 5 it gets into the regenerative cartridge 8.
Regenerative cartridge absorbs carbon dioxide and moisture from the
gas mixture and releases the volume of oxygen proportional to the
volume of absorbed substances. Breathing mixture from regenerative
cartridge 8 goes to breathing bag 9.
When the user inhales, oxygen-enriched gas mixture from the breathing
bag 9 re-enters the cartridge 8 where it is further purified from carbon
dioxide and returns to the half-mask 4 to the respiratory organs through
the breathing tube 5.
Surplus breathing mixture during exhale leaves the breathing bag 9
through the relief valve 10.
To fill the breathing bag 9 and provide oxygen in the first minutes after
donning the escape hood, activate the starter by pulling the cord up.
After putting on the hood, one can tighten or loosen the adjusting
belts 6 so that the regenerative cartridge 8 does not stretch the
breathing tube 5.
The design of the hood 1 and half mask 4 provides reliable obturation
and no additional external headband straps are necessary.
When the oxygen-containing product in the cartridge absorbs carbon
dioxide and moisture, heat is released. The surface of the cartridge
and the breathing mixture therefore heat as well. This indicates,
that the escape hood is operating correctly, and it should not cause
any anxiety.
Summary of Contents for EmSCAPE