Hood 1 has reflective element 2, window 3, half-mask 4. With elastic 

straps of the hood, that require no adjustment, half-mask 4 tightly fits 

human face. Obturator at the bottom of the hood prevents the suction 

of toxic substances under the hood. 

Gas mixture in the breathing system of the escape hood circulates 

within the pendulum scheme of flow.

During exhale breathing mixture goes through half-mask 4, then 

through breathing tube 5 it gets into the regenerative cartridge 8. 

Regenerative cartridge absorbs carbon dioxide and moisture from the 

gas mixture and releases the volume of oxygen proportional to the 

volume of absorbed substances. Breathing mixture from regenerative 

cartridge 8 goes to breathing bag 9.

When the user inhales, oxygen-enriched gas mixture from the breathing 

bag 9 re-enters the cartridge 8 where it is further purified from carbon 

dioxide and returns to the half-mask 4 to the respiratory organs through 

the breathing tube 5. 

Surplus breathing mixture during exhale leaves the breathing bag 9 

through the relief valve 10.

To fill the breathing bag 9 and provide oxygen in the first minutes after 

donning the escape hood, activate the starter by pulling the cord up.

After putting on the hood, one can tighten or loosen the adjusting  

belts 6 so that the regenerative cartridge 8 does not stretch the 

breathing tube 5.

The design of the hood 1 and half mask 4 provides reliable obturation 

and no additional external headband straps are necessary. 

When the oxygen-containing product in the cartridge absorbs carbon 

dioxide and moisture, heat is released. The surface of the cartridge 

and the breathing mixture therefore heat as well. This indicates, 

that the escape hood is operating correctly, and it should not cause  

any anxiety.

Summary of Contents for EmSCAPE

Page 1: ...USER manual SKTB 02 SPTU 00 000 РЭ 01 S 20CN1 NSH TUENUA Emergency escape hood DEZEGA EmSCAPE Red 30 04 2020_V1 ...

Page 2: ......

Page 3: ...ION AND OPERATING PRINCIPLE 5 Purpose 5 Technical data 6 Scope of supply 7 Design and operation 8 Marking and sealing 10 Packaging 11 Manufacturer s warranty 11 INTENDED USE 12 TECHNICAL MAINTENANCE 13 TRANSPORTATION AND STORAGE 14 DISPOSAL 14 ...

Page 4: ...e hood and its parts the rules of use storage and transportation instructions for maintenance and disposal The escape hood meets the requirements of the TOR U 32 9 39548007 003 2019 and Technical Regulation for PPE of Ukraine Resolution of Cabinet of Ministers of Ukraine 761 dated 27 08 2008 The escape hood is intended for use by adults and children from 12 years No special personnel training for ...

Page 5: ...ion and chemical contamination caused by self inflicted accidents with the formation of chemically hazardous substances as well as from terrorist acts involving the use of toxic agents radioactive dust biological aerosols and poisonous inhalants in the field of labor protection to protect working personnel in hazardous industries related to the production extraction storage transportation and util...

Page 6: ... resistances 1300 Temperature of inhaled gas С F no more than 50 122 O2 content in the inhaled gas during rated working duration at least 21 Weight of the working part of the escape hood kg no more than 1 4 Dimensions in box bag mm no more than length 204 180 width 129 160 height 158 160 CO2 content in the inhaled gas during rated working duration max at lung ventilation 30 l min at lung ventilati...

Page 7: ...E in a sealed package that is put into box or bag pcs 1 User Manual copy 1 Label copy 1 Examples of identification articles when ordering DEZEGA EmSCAPE S 20CN1 NSH TUENUA IK 5 5 x x 5 5 the escape hood in the cardboard box S 20CN1 NSH TUENUA PK 5 5 x x 5 5 the escape hood in the bag The following are available on request SKTB 02 ПС20 46 00 000 fastening for wearing on a waist belt SKTB 02 ПС20 47...

Page 8: ...f the escape hood Picture 1 includes hood 1 with half mask 4 regenerative cartridge 8 breathing bag 9 Picture 1 Working part of the escape hood 1 fireproof hood 2 reflective element 3 window 4 half mask 5 breathing tube 6 adjusting belts 7 starter 8 regenerative cartridge with oxygen containing product 9 breathing bag 10 relief valve 1 2 3 4 5 6 7 8 9 10 ...

Page 9: ...re from the breathing bag 9 re enters the cartridge 8 where it is further purified from carbon dioxide and returns to the half mask 4 to the respiratory organs through the breathing tube 5 Surplus breathing mixture during exhale leaves the breathing bag 9 through the relief valve 10 To fill the breathing bag 9 and provide oxygen in the first minutes after donning the escape hood activate the start...

Page 10: ...month YY year of production the date of manufacture and the end of the shelf life month year the escape hood article S 20CN1 NSH pictograms of the donning procedure working duration of the escape hood minutes the rules for safe operation recordkeeping storage transportation and disposal information on forbiddance of unauthorized use of escape hoods age restrictions and restrictions related to phys...

Page 11: ... working part and ensures the air tightness of the escape hood during storage The top of the package is tightly sealed and has an incision in the middle from the edge to the welding line for easy opening The package with the working part lies upwards in the individual package Escape hoods in boxes are packed in 12 pcs in transport packaging cardboard boxes MANUFACTURER S WARRANTY The manufacturer ...

Page 12: ... your head hold the tube pull the half mask and adjust it so that it fits your face tightly Exhale and continue breathing to activate the starter pull the starter cord up exhale and continue breathing leave the emergency area CAUTION USERS WITH LONG HAIR AND VOLUMINOUS HAIRSTYLES NEED TO HIDE THEIR HAIR COMPLETELY UNDER THE HOOD If there is difficulty in breathing while moving stop without doffing...

Page 13: ...C 140 F The escape hood should not be used by people younger than 12 years old or having a neck circumference of less than 30 cm Possible malfunctions during donning and use of the escape hood and the ways to eliminate them Name of malfunctions their manifestation and additional indicators Possible reason Troubleshooting method Lack of air for inhalation No inhalation exhalation before donning Pul...

Page 14: ...4 F Transportation conditions at ambient temperature from minus 40 C to plus 50 C from 40 to 122 F Escape hoods must be stored separately from aggressive and combustible substances Packages should be located not more than five pieces in a stack or on racks at a distance of at least 1 m from the heaters Ready for use escape hoods should be stored in the users workplace or in containers on escape ro...

Page 15: ...ducts marked with this symbol must be disposed of separately from household waste When the product reaches its end of life take it to a collection point designated by your local Organizations that provide escape hoods disposal services Separate collection and recycling of your goods during disposal will help to conserve natural resources and make sure that it is recycled safely for human health an...