Problems
Probable causes
Corrective actions
The compressor
does not shut off
The safety valve of the tank will
be activated.
It is necessary to contact the nearest
authorised Support Service for the repair.
The compressor
will not start
No Power
Check Voltage and Ensure switch is
switched on
Check if the motor has overheated for
some reason, causing the temperature
protector to open. Set the switch to «OFF»
state before restarting, and remove the
plug. After the motor cools down, make
sure to connect to the correct power
outlet, and then turn the switch to «ON».
The compressor is difficult to
start
• Whether the voltage of the mains
corresponds to that on the specification
plate
• Whether electrical extension cables are
being used with a faulty core or length.
• Whether the operating environment is
too cold (below 0°C).
• Whether there is electricity supply (plug
properly connected, magneto-thermal
fuses not broken).
Air loss
May be caused by a poor seal of
a connection.
• Check all air connections by wetting
them with a soapy water solution (
Never use the solution nearby electric
connections )
• When the tank is empty and being filled.
The user might hear a sisseling sound by
the pressure switch. This is normal and
will stop before the compressor reach a
pressure of 1.5 bar
• Check if the drain valve ( 14 ) is closed
well
8. TROUBLE SHOOTING
Should the machine fail to function correctly, a number of possible causes and the appropriate
solutions are given below:
13
EN
Summary of Contents for JL811201
Page 1: ...2020 01 Air Compressor JL811201 2 EAN CODE 3276000362685 PL RU UA RO EN...
Page 17: ...JL811201 2 RU N 128 3 02 2019 141031 1 5 02 2019...
Page 18: ...16 93 RU 2...
Page 20: ...1 2 3 4 5 6 7 8 9 10 11 RU 4...
Page 21: ...0 40 C 3 0 1 2 RU 5...
Page 22: ...a b c 7 2 RU 6...
Page 23: ...230 50 16 10 0 C 2 SAFETY INSTRUCTIONS RU 7...
Page 25: ...5 10 100 12 13 RU 9...
Page 26: ...6 5 8 8 7 5 8 5 3 0 3 I 2 8 6 RU 10...
Page 27: ...0 0 work on the motor 6 7 5 6 7 5 7 7 RU 11...
Page 28: ...7 ISO 68 SAE 10W 30 50 2 14 1 2 50 50 4 RU 12...
Page 29: ...OFF ON 0 C 1 5 14 8 RU 13...
Page 30: ...8 9 10 1 24 2 3 4 5 WEEE RU 14...
Page 31: ...6 7 8 10 RU 15...
Page 33: ...16 93 UA 2...
Page 35: ...1 2 3 4 5 6 7 8 9 10 11 4 UA...
Page 36: ...0 40 3 0 OFF a 1 2 5 UA...
Page 37: ...b c 7 2 6 UA...
Page 38: ...230 50 16 10 0 C 2 7 UA...
Page 40: ...5 10 100 12 13 9 UA...
Page 41: ...6 5 8 8 7 5 8 5 3 0 3 2 8 6 10 UA...
Page 42: ...0 0 6 7 5 6 7 5 7 7 11 UA...
Page 43: ...7 ISO 68 SAE 10W 30 50 50 4 50 2 14 1 2 12 UA...
Page 44: ...OFF ON 0 1 5 14 8 13 UA...
Page 45: ...8 9 10 1 2 3 4 5 6 7 8 WEE 14 UA...
Page 75: ......