background image

Cleaning

Regularly clean the machine housing with a soft cloth, preferably after each use. Keep the
ventilation slots free from dust and dirt. 
If the dirt does not come off use a soft cloth moistened with soapy water. Never use solvents
such as petrol, alcohol, ammonia water, etc.These solvents may damage the plastic parts.

Drain the tank

Compressing air will cause water in the tank.
Regularly drain the water from the tank to prevent tank corrosion :
•  First reduce the pressure in the tank till approximately 2 bar by connecting and activating an 

air tool .

• Then slowly turn the drain valve (14) on the lower side of the tank open.

The machine has been designed to operate over a long period of time with a minimum of
maintenance. Continuous satisfactory operation depends upon proper machine care and 

regular cleaning. Before interfering in any way whatsoever with the compressor, please make 

sure that:
• The switch button is in the “0” position and the power plug is removed from the power socket
• The air tank is fully decompressed (both pressure gauges must be pointed at 0 Bar)
• The air in the tank can be eliminated by the air tool.

Make sure that the plug is removed from the mains when carrying 

out maintenance

6. OPERATION

7.  MAINTENANCE  

• Activate the air tool shortly, so the pressure gauge (7) will show the right pressure level
•   Turn the pressure regulator turning knob (5) clockwise, till the pressure gauge (7) shows the 

pressure level you need

•  Your air tool is now ready to use. 

Note: when not connecting an air tool while adjusting the pressure, it 

might occur the pressure gauge (7) is not reacting accurately on the 

pressure drop

11

EN

Summary of Contents for JL811201

Page 1: ...2020 01 Air Compressor JL811201 2 EAN CODE 3276000362685 PL RU UA RO EN...

Page 2: ...e opiekuna lub po uzyskaniu od niego stosownych wskaz wek Ryzyko obra e cia a utraty ycia lub uszkodzenia narz dzia w przypadku nieprzestrzegania zalece podanych w niniejszej instrukcji Ryzyko pora en...

Page 3: ...ustawione fabrycznie zapewniaj c maksymalnie bezpieczn obs ug WARNING DRAIN MOISTURE FROM TANK EVERY WEEK PREVENT TANK CORROSION WARNING HOT SURFACES DO NOT TOUCH Allow to cool before servicing WARNIN...

Page 4: ...trukcje dotycz ce bezpiecze stwa 3 Opis 4 Dane techniczne 5 Przed rozpocz ciem u ywania urz dzenia 6 U ytkowanie 7 Konserwacja 8 Rozwi zywanie problem w 9 Utylizacja i recykling 10 Gwarancja 11 Deklar...

Page 5: ...transportowa spr arki ze zbiornikiem pod ci nieniem Niekt re cz ci spr arki np g owica oraz przewody doprowadzaj ce mog osi gn wysokie temperatury Nie dotyka tych cz ci by unikn oparze Do transportu s...

Page 6: ...yw zabezpieczaj cych by unikn uraz w fizycznych i uszkodzenia spr arki Nie u ywa spr arki jako t pego narz dzia na osobach przedmiotach lub zwierz tach by unikn powa nych uszkodze Je li spr arka nie j...

Page 7: ...ochronnym Mo e ona by pod czona a do dowolnego gniazdka ze stykiem ochronnym 230V 50Hz z bezpiecznikiem 16A D ugie przewody zasilaj ce jak r wnie przed u acze kable b bnowe itp powoduj spadek napi ci...

Page 8: ...0 Bar Ci ar 25kg Cylinder 1 Poziom mocy akustycznej LwA K 3dB A 93 dB A Ci nienie akustyczne LwA K 3dB A 73 dB A 1 Pokrywa 2 Uchwyt 3 Prze cznik 4 ruba spustowa 5 Regulator ci nienia 6 Szybkoz czka r...

Page 9: ...one spa i odpowiednio je przymocowa Spr arka powinna znajdowa si co najmniej 100 cm od ciany aby zapewni dobr wentylacje i skuteczne ch odzenie Zaleca si u ywanie blokad do k by zapobiec ruchowi podc...

Page 10: ...nana przez osoby z odpowiednimi kwalifikacjami Spr arka jest wyposa ona w dwa manometry i jeden punkt do pod czenia w a do powietrza Manometr 7 po prawej stronie ci nienie wylotowe Ci nienie w rym wyl...

Page 11: ...ozycji 0 a wtyczka zasilaj ca jest wyj ta z gniazdka Zbiornik z powietrzem jest ca kowicie odpr ony oba manometry musz znajdowa si w pozycji 0 bar w Usun powietrze ze zbiornika za pomoc narz dzia pneu...

Page 12: ...o osi gni cia poziomu oznaczonego na wzierniku Po ka dej wymianie lub uzupe nieniu oleju urz dzenie nale y wyczy ci by usun wszelkie lady oleju na nim i zmniejszy ryzyko po aru Wyczy ci filtr powietrz...

Page 13: ...napi cie domowej sieci odpowiada napi ciu na tabliczce znamionowej czy przed u acze nie s u ywane z wadliwym stykiem lub niew a ciw d ugo ci czy otoczenie robocze nie jest zbyt zimne poni ej 0 C Czy j...

Page 14: ...a Dotyczy to m in prze cznik w wy cznik w obwodu zabezpieczaj cego i silnika w przypadku zu ycia 5 Roszczenie gwarancyjne mo e by rozpatrzone tylko pod nast puj cymi warunkami Dostarczenie w postaci p...

Page 15: ...nie z naszymi warunkami sprzeda y i dostawy 7 Uszkodzonenarz dziazwracanedodealerapodwarunkiemodpowiedniegoichzapakowania 8 Firma odm wi przyj cia produkt w kt rych opakowanie b dzie niew a ciwe lub w...

Page 16: ...A1 2009 EN 55014 1 2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 IEC 62321 2 2013 IEC 62321 1 2013 IEC 62321 3 1 2013 IEC 62321 5 2013 IEC 62321 4 2013 IEC 62321 7 1 2015 IEC 62321 7 2 201...

Page 17: ...JL811201 2 RU N 128 3 02 2019 141031 1 5 02 2019...

Page 18: ...16 93 RU 2...

Page 19: ...ot adjust factory settings To reduce risk of electrical shock do not remove cover Pressure controls set by factory for maximum safe operation Serial n Made in P R C 2018 200 l min 125 l min 1 24 l ADE...

Page 20: ...1 2 3 4 5 6 7 8 9 10 11 RU 4...

Page 21: ...0 40 C 3 0 1 2 RU 5...

Page 22: ...a b c 7 2 RU 6...

Page 23: ...230 50 16 10 0 C 2 SAFETY INSTRUCTIONS RU 7...

Page 24: ...3 4 JL811201 220 240 50 1 5 2850 IP IP 20 24 125 200 8 25 1 LwA K 3 A 93 A LwA K 3 A 73 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 10 11 4 5 3 2 12 13 14 7 8 9 6 RU 8...

Page 25: ...5 10 100 12 13 RU 9...

Page 26: ...6 5 8 8 7 5 8 5 3 0 3 I 2 8 6 RU 10...

Page 27: ...0 0 work on the motor 6 7 5 6 7 5 7 7 RU 11...

Page 28: ...7 ISO 68 SAE 10W 30 50 2 14 1 2 50 50 4 RU 12...

Page 29: ...OFF ON 0 C 1 5 14 8 RU 13...

Page 30: ...8 9 10 1 24 2 3 4 5 WEEE RU 14...

Page 31: ...6 7 8 10 RU 15...

Page 32: ...ot CS 00001 59790 RONCHIN France 13 01 2020 11 RU 16 EN 1012 1 2010 EN 60204 1 June 2006 A1 2009 EN 55014 1 2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 IEC 62321 2 2013 IEC 62321 1 2013 I...

Page 33: ...16 93 UA 2...

Page 34: ...ot adjust factory settings To reduce risk of electrical shock do not remove cover Pressure controls set by factory for maximum safe operation Serial n Made in P R C 2018 200 l min 125 l min 1 24 l ADE...

Page 35: ...1 2 3 4 5 6 7 8 9 10 11 4 UA...

Page 36: ...0 40 3 0 OFF a 1 2 5 UA...

Page 37: ...b c 7 2 6 UA...

Page 38: ...230 50 16 10 0 C 2 7 UA...

Page 39: ...3 4 JL811201 220 240 50 1 5 2850 1 IP 20 24 125 200 8 0 25 1 LwA K 3 93 A LwA K 3 73 A 1 p 2 3 4 5 6 7 8 9 10 11 12 13 14 1 10 11 4 5 3 2 12 13 14 7 8 9 6 8 UA...

Page 40: ...5 10 100 12 13 9 UA...

Page 41: ...6 5 8 8 7 5 8 5 3 0 3 2 8 6 10 UA...

Page 42: ...0 0 6 7 5 6 7 5 7 7 11 UA...

Page 43: ...7 ISO 68 SAE 10W 30 50 50 4 50 2 14 1 2 12 UA...

Page 44: ...OFF ON 0 1 5 14 8 13 UA...

Page 45: ...8 9 10 1 2 3 4 5 6 7 8 WEE 14 UA...

Page 46: ...00001 59790 RONCHIN France 13 01 2020 15 EN 1012 1 2010 EN 60204 1 June 2006 A1 2009 EN 55014 1 2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 IEC 62321 2 2013 IEC 62321 1 2013 IEC 62321 3 1...

Page 47: ...struite de c tre o persoan responsabil Indic risculdeaccidentare decessaudefectareasculei ncazdenerespectare a instruc iunilor din acest manual Risc de electrocutare Risc de nc lzire Aten ie compresor...

Page 48: ...i setate din fabric pentru func ionarea la maxim siguran WARNING DRAIN MOISTURE FROM TANK EVERY WEEK PREVENT TANK CORROSION WARNING HOT SURFACES DO NOT TOUCH Allow to cool before servicing WARNING Do...

Page 49: ...presorului 2 Instruc iuni privind siguran a 3 Descriere 4 Date tehnice 5 nainte de punerea n func iune a echipamentului 6 Func ionarea 7 ntre inerea 8 Depanarea 9 Eliminarea i reciclarea 10 Garan ie 1...

Page 50: ...sau animale Nu transporta i compresorul cu rezervorul presurizat Anumite componente ale compresorului precum capul i evile de alimentare sepot ncingefoartetare Nuevita iacestecomponentepentruaevitaar...

Page 51: ...za i compresorul ca i un instrument neascu it mpotriva persoanelor obiectelor sau animalelor pentru a preveni deterior ri grave n cazul neutiliz rii compresorului ntotdeauna scoate i techerul din priz...

Page 52: ...sta poate fi conectat la o priz rezistent la ocuri de 230V 50Hz protejat cu o siguran de 16A Cablurile de alimentare lungi prelungitoarele tambururile de cablu etc pot cauza o sc dere a tensiunii i mp...

Page 53: ...5kg Cilindri 1 Nivel de putere sonor LwA K 3dB A 93 dB A Nivel de presiune sonor LwA K 3dB A 73 dB A 1 Capac 2 M ner 3 ntrerup tor 4 urub de scurgere 5 Regulator de presiune 6 Racord rapid presiune ev...

Page 54: ...igura i v c acestea nu risc s cad ancor ndu le bine Pentru aerisire corect i r cire eficient este important ca compresorul s fie pozi ionat la cel pu in 100cm de perete V recomand m utilizarea fr nei...

Page 55: ...n punct de conectare a furtunului de aer Monometrul 7 de pe dreapta presiune pe evacuarea Presiunea acestei evacu ri poate fi reglat cu ajutorul regulatorului de presiune 5 Manometrul 8 de pe st nga p...

Page 56: ...ul de aer este complet depresurizat ambele manometre trebuie s indice 0 Bari Aerul din rezervor poate fi eliminat cu scula de aer Asigura i v c techerul este decuplat de la priz c nd efectua i opera i...

Page 57: ...indicat de pe hubloul de sticl este ob inut Dup fiecare schimbare de ulei sau de umplere p stra i ma ina curat pentru a v asigura c produsul nu con ine ulei rezidual i pentru a reduce riscul de incen...

Page 58: ...cu cea de pe pl cu a tehnic Asigura i v c prelungitoarele electrice nu con in conductori defec i sau s aib lungimea inadecvat Temperatura de func ionare este prea sc zut sub 0 C Verifica i alimentarea...

Page 59: ...mutatoare de protec ie a circuitelor i motoarelor n cazul uzurii 5 Preten ia dumneavoastr cu privire la garan ie poate fi procesat numai dac Pute i oferi dovada datei de achizi ie sub forma un bon de...

Page 60: ...ric iile de utilizare a anumitor substan e periculoase n echipamentele electrice i electronice ce amendeaz a Directivei 2011 65 UE privind restric iile de utilizare a anumitor substan e periculoase n...

Page 61: ...y if they are supervised or instructed by a responsible person Denotes risk of personal injury loss of life or damage to the tool in case of nonobservance of the instructions in this manual Risk of el...

Page 62: ...tch warning Label Do not adjust factory settings To reduce risk of electrical shock do not remove cover Pressure controls set by factory for maximum safe operation WARNING DRAIN MOISTURE FROM TANK EVE...

Page 63: ...Compressor 2 Safety Instructions 3 Description 4 Technical data 5 Before putting the equipment into Operation 6 Operation 7 Maintenance 8 Trouble Shooting 9 Disposal and recycling 10 Warranty 11 CE D...

Page 64: ...ons or animals Do not transport the compressor with the tank pressurised some parts of the compressor such as the head and the feed through pipes may reach high temperatures Do not touch these parts t...

Page 65: ...damage to the compressor Do not use the compressor as a blunt instrument against persons objects or animals in order to prevent serious damage If the compressor is no longer in use always take the plu...

Page 66: ...econnectedtoany230V 50Hzshockproofsocketwhichisprotectedbya16A fuse Long supply cables extensions cable reels etc cause a drop in voltage and can impede motor start up Do not use cables longer than 10...

Page 67: ...re 8 0 Bar Weight 25kg Cylinder 1 Sound power level LwA K 3dB A 93 dB A Sound pressure LwA K 3dB A 73 dB A 1 Cover 2 Handle 3 Switch 4 Drain screw 5 Pressure regulator 6 Quick coupler regulated outlet...

Page 68: ...oard or a shelf of a bookcase just make sure that they cannot fall down by securing them properly For proper ventilation and effective cooling it is important that the compressor is positioned at leas...

Page 69: ...re gauge 8 on the left tank pressure Hints for accurate adjustment of the pressure regulation Turn the pressure regulator turning knob 5 anti clockwise till pressure is fully released Connect the air...

Page 70: ...of maintenance Continuous satisfactory operation depends upon proper machine care and regular cleaning Before interfering in any way whatsoever with the compressor please make sure that The switch bu...

Page 71: ...d screw back the screw Fill the oil via the upper hole of the sump lid until the level indicated on the inspection glass has been reached After each oil change or replenishment keep the machine clean...

Page 72: ...ns corresponds to that on the specification plate Whether electrical extension cables are being used with a faulty core or length Whether the operating environment is too cold below 0 C Whether there...

Page 73: ...nd motors in the event of wear 5 Your claim upon the warranty can only be processed if Proof of the purchase date can be provided in the form of a receipt No repairs and or replacements have been carr...

Page 74: ...1012 1 2010 EN 60204 1 June 2006 A1 2009 EN 55014 1 2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 IEC 62321 2 2013 IEC 62321 1 2013 IEC 62321 3 1 2013 IEC 62321 5 2013 IEC 62321 4 2013 IEC...

Page 75: ......

Page 76: ...ble d posez le en d ch terie Notice trier Pour en savoir plus www quefairedemesdechets fr Ten produkt poddawany jest recyklingowi kiedy przestaje by u yteczny nale y dostarczy go do punktu zbi rki odp...

Reviews: