58
Burner Tube Removal
1.
Remove gas valve assembly, (See Gas Valve And Manifold Removal).
2.
Remove the six 5/16 screws, lift up tube and slide out rear of burner housing.
3.
Re-assemble in reverse order, (Note: when reinstalling burner tubes make sure gas holes are on
top).
High Limit Thermostat Locations & Functions Burner Housing
This hi-limit is located on the rear of the burner housing.
1: The thermostat opens the circuit to the main burners in the event of malfunction in the gas
control area or temperature control. This thermostat will open quickly if there is a significant loss
of air flow over the burner area.
2: It is held in place by two screws. There are spacers between the thermostat and bracket which
must be used to give proper operation.
Removal :
To remove the hi-limit thermostat on the side of the burner housing, remove
the terminal of each wires attached to the thermostat. Lastly, remove the mounting screws
holding the thermostat to the burner housing.
5/16” Gas Valve Bracket Screws
High Limit Thermostat
Part # 8533-125-001 7/21
Summary of Contents for DN0120
Page 10: ...10 Part 8533 125 001 7 21 Notes ...
Page 11: ...11 Part 8533 125 001 7 21 Section 1 Dryer Specifications and Mounting ...
Page 13: ...13 Machine Dimensions Front View Part 8533 125 001 7 21 ...
Page 14: ...14 Machine Dimensions 120Lb Part 8533 125 001 7 21 ...
Page 15: ...15 Machine Dimensions 120Lb Part 8533 125 001 7 21 ...
Page 16: ...16 Part 8533 125 001 7 21 Notes ...
Page 17: ...17 Part 8533 125 001 7 21 Section 2 Dryer Installation ...
Page 23: ...23 Part 8533 125 001 7 21 Notes ...
Page 24: ...24 Part 8533 125 001 7 21 Notes ...
Page 25: ...25 Part 8533 125 001 7 21 Section 3 Dryer Operating Programing Instructions ...
Page 43: ...43 Part 8533 125 001 7 21 Notes ...
Page 44: ...44 Part 8533 125 001 7 21 Notes ...
Page 45: ...45 Part 8533 125 001 7 21 Section 4 Service Procedures Trouble Shooting and Schematics ...
Page 69: ...69 Part 8533 125 001 7 21 Notes ...
Page 82: ...82 Wiring Schematic 11 Part 8533 125 001 7 21 ...
Page 83: ...83 Wiring Diagram 11 Part 8533 125 001 7 21 ...
Page 84: ...84 Wiring Schematic 10 Part 8533 125 001 7 21 ...
Page 85: ...85 Wiring Diagram 10 Part 8533 125 001 7 21 ...
Page 86: ...86 Part 8533 125 001 7 21 Notes ...
Page 87: ...87 DN0120NE 11EO1_ DN0120NE 10EO1_ Part 8533 125 001 7 21 Section 5 Dryer Parts Data ...
Page 89: ...89 3 1 2 10 12 14 15 18 7 8 9 19 21 16 5 6 4 13 11 16 14 15 Part 8533 125 001 7 21 ...
Page 91: ...91 12 14 17 19 20 23 5 6 15 16 9 22 13 11 8 5 24 25 26 27 Part 8533 125 001 7 21 ...
Page 93: ...93 1 1 2 4 3 Part 8533 125 001 7 21 ...
Page 95: ...95 3 1 2 10 12 7 5 6 4 9 11 8 6 19 Part 8533 125 001 7 21 ...
Page 101: ...101 3 1 2 10 12 14 7 5 6 4 9 13 11 8 Part 8533 125 001 7 21 ...
Page 107: ...107 Part 8533 125 001 7 21 Notes ...
Page 108: ...108 3 1 2 12 13 14 17 20 16 23 5 4 15 9 10 24 27 11 25 32 31 30 33 Part 8533 125 001 7 21 ...
Page 111: ...111 1 2 3 4 5 6 8 9 Part 8533 125 001 7 21 ...
Page 113: ...113 14 2 3 4 5 7 6 5 12 9 10 11 13 16 15 17 18 19 Part 8533 125 001 7 21 ...
Page 114: ...114 Part 8533 125 001 7 21 ...
Page 115: ...115 Part 8533 125 001 7 21 ...
Page 116: ...116 Wiring Schematic 11 Part 8533 125 001 7 21 ...
Page 117: ...117 Wiring Diagram 11 Part 8533 125 001 7 21 ...
Page 118: ...118 Wiring Schematic 10 Part 8533 125 001 7 21 ...
Page 119: ...119 Wiring Diagram 10 Part 8533 125 001 7 21 ...
Page 120: ...120 Part 8533 125 001 7 21 Notes ...
Page 121: ...121 DN0120NE 39AO1_ Part 8533 125 001 7 21 Section 6 50Hz Dryer Parts Data ...
Page 123: ...123 Part 8533 125 001 7 21 Notes ...
Page 124: ...124 Wiring Schematic 39 Part 8533 125 001 7 21 ...
Page 125: ...125 Wiring Diagram 39 Part 8533 125 001 7 21 ...
Page 126: ...126 Part 8533 125 001 7 21 Notes ...
Page 127: ...127 Part 8533 125 001 7 21 Section 7 Maintenance Schedule ...