dexPro DXU10SS Instruction Manual Download Page 6

 

DXU10SS DELUX STAINLESS STEEL

User Instructions

 

The heater must be filled with water before connection to the electrical supply.

 

When powering up for the first time, you must verify that the temperature

 

indicator (light) extinguishes when the required temperature is reached.

 

The heater only switches on again if the temperature falls below this setting. 

 

(See troubleshooting)

 

When filling for the first time, the hot water valve in the low-pressure tap fitting  

 

must be open so that water can flow into the device. If the device is not filled with  

 

water beforehand during installation, the automatic safety device will activate  

 

and switch off the appliance. (See troubleshooting instructions on how to act in  

 

the event of a fault).

    

Temperature setting

 

 

 

 

     Cold; heater is switched off.

         Automatic frost protection active; the device

 

 

 

 

     switches on if the water temperature falls 

 

 

 

 

     below 7  C.

         Water temperature has risen by approx 25°C.
         Energy-saver mode/reduced energy 

 

 

 

 

     consumption: Greater energy savings are possible  

 

 

 

 

     if the water temperature is set to a maximum of  

 

 

 

 

     +/- 55  C. This also reduces the risk of damage to  

 

 

 

 

     the device.

 

 

 

 

     Water temperature is +/- 75°C.

Operating the unit at a lower temperature can reduce scaling, save energy and reduce the 
risk of scalding.

To use the device, simply select the desired temperature setting from the listed options.
Once a setting is selected the indicator light will illuminate to signal the element is heating
the stored water to the desired temperature. When the light extinguishes the temperature
setting has been achieved. When reducing the temperature setting of the heater, it will
not take effect until the water has cooled below the new temperature set point.

e

Usage and Maintenance

Please refer to the previous section for details of the thermostat settings. We recommend
you use position “E“ as this guarantees maximum energy efficiency by maintaining the 
water temperature at approximately 55

°

C; furthermore lime scale build-up and heat loss 

are much lower than at higher temperatures.
Operation of the device is indicated by the indicator light, which lights up when the device
is on and extinguishes when the set temperature is reached or the device is turned off.

    

For vented systems, during heating, the volume of the water in the device 

 

expands, causing a flow of water (“expansion water“) from the from vented tap. 

 

The tap will naturally drip during its heating cycle. This is perfectly normal and no 

 

preventive action needs to be taken. Further tightening the tap handle will not 

 

prevent the flow of expansion water. This may damage the tap.

Frost

 

When the device has not been used for a couple of months, it must be protected  

 

against the effects of frost. Leave the power supply on and set the thermostat  

 

knob to”*“. When set to this position, the device maintains the water temperature  

 

at approximately 7

°

C. If you will not use the device for more than half a year,  

 

unplug it, disconnect it from the water supply and empty it. To that end, hold the  

 

device with the connection hoses upwards. Remove the connection hoses. Then  

 

hold the device, with the connections pointing downwards, over a sink. Caution:  

 

the boiler will release 5 litres of water.

Maintenance

 

This heater does not require any maintenance by the user. Professional 

 

maintenance should always be carried out by an expert.

 

If faulty, never try to repair the heater yourself. Please contact the nearest service

 

specialist or the party that supplied the appliance originally.

De-scaling

service inspection should be performed by authorized and qualified technical staff every 
year. De-scaling of the device during this inspection is highly recommended, especially
when you live in an area with hard water exceeding 12

°

dH (German standard of 

hardness). Higher water temperature will intensify calcification. It is therefore recommend-
ed to set the device at maximum 55

°

C (energy-saving setting) in areas with extremely

hard water >16

°

dH.

Cleaning

The housing of the device can simply be cleaned with a damp cloth. Do not use aggressive
cleaners or cleaners with a scouring effect!

e

*

*

Summary of Contents for DXU10SS

Page 1: ...Tel 01244 631370 Email sales dexprouk com INSTRUCTION MANUAL DXU10SS Delux Stainless Steel water heater...

Page 2: ...the use of carefully selected materials and an improved manufacturing process ensure high quality Complies with the basic safety standards set by European Directives Failure to observe the instruction...

Page 3: ...in accordance with the drawing on page 6 7 of the user manual Any other installation position may result in serious damage to the device Installation should take place as close as possible to a cold w...

Page 4: ...ure is below 4 2 bar and hot water expansion cannot be accommodated in the pipework Install 3 Pressure is above 4 2 bar and hot water expansion cannot be accommodated in the pipework Mixer tap flexi h...

Page 5: ...ust be full of water and tested for leaks before powering on the unit Electrical installation must be carried out by a qualified electrician in accordance with the latest edition of the IEE wiring reg...

Page 6: ...hermore lime scale build up and heat loss are much lower than at higher temperatures Operation of the device is indicated by the indicator light which lights up when the device is on and extinguishes...

Page 7: ...ting water Heating element defective Scale deposits in the flow regulator Thermostat set too high Water pressure too low Thermostat and safeguard defective Too much scale deposit in the device There i...

Page 8: ...Notes Notes...

Page 9: ...Tel 01244 631370 Email sales dexprouk com...

Reviews: