dexPro DXU10SS Instruction Manual Download Page 3

 

 

Children shall not play with the appliance. Cleaning and user maintenance shall

 

not be made by children without supervision.

Declaration of conformity

This boiler complies with the following directives and standards:

• 2006/95/EC Low Voltage Directive

• 2004/108/EC Electromagnetic Compatibility Directive

• 2011/65/EC (RoHS II)

• 2009/125/EC Eco design

• (EC) No. 814/2013

And also comply with the provisions of the following European Standards:

• EN 62233:2008 + C1:2008

• EN 61000-3-2:2014

• EN 61000-3-3:2013

• EN 60335-1:2012 + AII:2014 + A13:2017

• EN 60335-2-35:2016

• EN 55014-1:2017

• EN 55014-2:2015

Environment

This device is delivered in sturdy packaging in order to avoid damage during transport.
This packaging consists mainly of recyclable materials. We request that you dispose of the 
packaging accordingly for recycling.

Disposal of the appliance

 

Old appliances must not be disposed of in your household waste! Every 

 

consumer is legally obliged to dispose of old appliances separately from their

 

household waste and to take them, for example, to a collection point in their local  

 

communityor local district. Old electrical appliances will be accepted there free  

 

of charge. This ensures that the old appliances are properly recycled and any  

 

negative impacts on the environment are avoided. This is why electrical 

 

appliances are marked with the symbol shown on the left.

Installation

The device should be installed in accordance with the drawing on page 6/7 of the
user manual. Any other installation position may result in serious damage to the device.
Installation should take place as close as possible to a cold water connection. The product
should be protected from the effects of frost (for example in caravans, summer houses, 
etc.).

 

This unit should not be installed in a location where it is at risk of freezing.

 

This unit is not to be used with thermostatic mixing valves/taps or for 

 

supplying a mixer tap.

 When installing, consider any risks posed by potential leaks from the product or 

   pipework. Avoid installation in areas where a leak could have potentially severe 
   consequences, such as near electronic equipment

 Check for potential freezing of the pipework or heater and take action if required, such 

  as lagging supply pipes.

 The heater should be located as close as practical to the hot water outlet as this avoids    

  heat losses through the pipework and improves performance.

DXU10SS DELUX STAINLESS STEEL

Connection to the water supply

The device must be installed as shown in the installation drawing.

 Left outlet of the device is the water inlet (cold/ blue), right outlet is the water outlet 

   (hot/red).

 Prepare the water connections to the tap. Make sure main water supply is switched off.

 

Make sure main power is switched off.

 Connect the water supply to the device and to the main water supply.

 Open the main water supply and check for leakage and release air from the system by 

   opening the hot water tap.

 When air has left the system, connect the device to the electric system.

 Heater should now function!

TP

Summary of Contents for DXU10SS

Page 1: ...Tel 01244 631370 Email sales dexprouk com INSTRUCTION MANUAL DXU10SS Delux Stainless Steel water heater...

Page 2: ...the use of carefully selected materials and an improved manufacturing process ensure high quality Complies with the basic safety standards set by European Directives Failure to observe the instruction...

Page 3: ...in accordance with the drawing on page 6 7 of the user manual Any other installation position may result in serious damage to the device Installation should take place as close as possible to a cold w...

Page 4: ...ure is below 4 2 bar and hot water expansion cannot be accommodated in the pipework Install 3 Pressure is above 4 2 bar and hot water expansion cannot be accommodated in the pipework Mixer tap flexi h...

Page 5: ...ust be full of water and tested for leaks before powering on the unit Electrical installation must be carried out by a qualified electrician in accordance with the latest edition of the IEE wiring reg...

Page 6: ...hermore lime scale build up and heat loss are much lower than at higher temperatures Operation of the device is indicated by the indicator light which lights up when the device is on and extinguishes...

Page 7: ...ting water Heating element defective Scale deposits in the flow regulator Thermostat set too high Water pressure too low Thermostat and safeguard defective Too much scale deposit in the device There i...

Page 8: ...Notes Notes...

Page 9: ...Tel 01244 631370 Email sales dexprouk com...

Reviews: