WATER FLOW SENSOR
This appliance has a water flow sensor that
will immediately ignite the burner when
detecting water flow.
FAN ASSISTED COMBUSTION
The motor and fan force oxygen into
the appliance to fuel the flame,
maximising efficiency.
LOW WATER PRESSURE
START UP
The appliance will activate from a
water flow of 3lt/min. This indicates
that it is suitable for low water
pressure applications.
AUTOMATIC GAS ADJUSTMENT
The appliance will automatically adjust its
gas usage depending on the water usage,
using less gas when you use less water,
making the appliance more efficient.
DRY COMBUSTION PROTECTION
In the event of dry combustion (when the
gas burner comes on with out water flow),
the appliance will automatically shut down
OVER PRESSURISATION
PROTECTION
The appliance will automatically protect
itself by releasing pressure if the water
supply is over 10 Bar (this can be manually
set).
FLAME OUT SENSOR
This is designed to automatically cut off
the gas supply should the flame/ burner
unexpectedly extinguish or the sensor no
longer detects a flame.
REMOTE DIGITAL CONTROL
PANEL
Simplicity of adjusting the temperature of
the water by 1°C increments at the touch
of a button.
LONGER LASTING
Due to the seal around the entire cover of
the geyser it gets far less exposed to harsh
elements such as wind, rain and sea air. It is
better protected and thus longer lasting.
THERMAL FUSE
The thermal fuse wraps around the
heat exchanger and heats up in subzero
temperatures preventing the water from
freezing inside the pipes, causing them
to burst.