9
253 mm
438,5 mm
13
2,
5
m
m
3,
3
Main System
DE-M071203E • DEWE-50-USB2-16-NI • Technical Reference Manual • Printing version 1.0.0 • Dec. 17, 2007
System specifications
DEWE-50-USB2-16-NI
16 slot signal conditioning with system isolation
(in conjunction with DEWE-DAQ modules)
A/D converter specs: see appendix A
Wiring to A/D converter: see appendix B
DEWE-50-xx
A/D converter interface:
�
USB 2.0
�
USB 1.x
�
IEEE 1394 (FireWire
®
)
Power supply:
�
230 V
AC
�
115 / 230 V
AC
(switchable)
�
100 to 250 V
AC
�
9 to 40 V
DC
�
10 to 32 V
DC
with UPS battery and external 115 / 230 V
AC
power supply
RS232 / 485 interface:
�
yes
�
no
Motherboard:
�
DAQ-MOTH-16-DE-x
�
5 V
�
10 V
�
DAQ-MOTH-16-NI-x-x
�
5 V
�
10 V
�
USB interface on-board
Operating temperature:
0 °C to 50 °C (standard)
Storage temperature:
-20 °C to +60 °C
Humidity (operating):
10 % to 80 %, non condensing
5 % to 95 %, rel. humidity
Vibration:
MIL-STD 810F 514.5 procedure I
operating test procedure
frequency range: 5 to 200 to 5 Hz; 5 x 12 min each direction
displacement amplitude ±3.5 mm (5 to 8.45 Hz)
acceleration amplitude 1 g (8.45 to 92 Hz)
displacement amplitude 92 to 113 Hz: ±0.029 mm
acceleration amplitude 1.5 g (113 to 200 Hz)
Shock:
MIL-STD 810F 516.5 procedure I
non operating test procedure
½ sinus 11 ms 10 g, 3 shocks positive, 3 shocks negative
Dimensions (W x D x H):
approx. 438 x 253 x 133 mm (17.2 x 10 x 5.2 in.)
with 50-MK option(3U 19" mountingrack): 513 x 256 x 133 (20.2 x 10.1 x 5.2 in.)
Weight:
typ. 5.5 kg (7 lbs), depending on configuration
Dimensions*
* Dimensions in mm
(1 inch = 25.4 mm)