Item 

1.1

 

ZG    button  6 

Click the ZG button, the actuator moves to ZG position, stop when click any button during the 

movement; 

Press  and hold  the ZG button for 5s, timer  LED of remote  flashes, the control box records 

current position as ZG position; 

When in the process of moving to memory positions, the head and foot actuators move first, 

then the tilt and lumbar actuators move; 

1.2

 

  AntiSnore button 9 

Click 

AntiSnore

 button, actuators move to 

AntiSnore

 position, stop when click any button 

during movement

 

Press and hold 

AntiSnore

 button for 5s, timer LED of remote flashes, the control box records 

current position as 

AntiSnore

 position; 

When in the process of moving to memory positions, the head and foot actuators move first, 

then the tilt and lumbar actuators move; 

1.3Head up button 4 

Press and hold 

HEAD UP button of remote, head actuator moves out, stop when 

released

 

1.4

 

Head down button 5 

Press and hold HEAD DOWN button of remote, head actuator moves in, stop when released

 

1.5

 

Foot up button 7 

Pressa and hold FOOT UP button of remote, foot actuator moves out, stop when released; 

2

 / 

4

 

Summary of Contents for RF405B

Page 1: ...hor User Manual of RF405B Edition 1 0 Page 1 of 4 User Manual of RF405B Figure 1 button ofremote Underbed Light ZEROG position Head Down M3 M4 up Head Up Antisnore EXTME1 position Flat Lounge position Foot down EXTME2 position Foot up MassageALL Sensor light M3 M4 down 1 4 ...

Page 2: ...ntiSnore position stop when click any button during movement Press and hold AntiSnore button for 5s timer LED of remote flashes the control box records current position as AntiSnore position When in the process of moving to memory positions the head and foot actuators move first then the tilt and lumbar actuators move 1 3Head up button 4 Press and hold HEAD UP button of remote head actuator moves ...

Page 3: ...y massage intensityswitches among 0 1 2 3 1 9 M3 M4 motor up button 11 Press and hold M3 M4 UP button of remote M3 M4 actuator moves out stop when released 1 10 M3 M4 motor down button 12 Press and hold M3 M4 down button of remote M3 M4 actuator moves in stop when released 1 11 Memory position button 10 and 13 14 Click memory position to move the actuator to the memory position Press and hold the ...

Page 4: ...e and Economic Development Canada licenceexempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d ISED applicables aux appareils radioexempts de licence L exploitation est autoris...

Reviews: