3A8110C
Testing the Switch Functionality
Follow the steps below to test your switch
functionality.
To Open Unit - All Units
1.
Remove battery, see
2.
Perform pressure relief procedure, see
3.
Turn unit on its side and remove ten
screws on clamshell.
4.
Pull clamshell open and remove switch
from slot in the clamshell. Pull switch free
by disconnecting the connector on the
end of the ribbon.
5.
Once open, follow testing procedure on
the following page.