E
ng
lish
3
CONTENTS
WARNINGS ........................................................................ 2-3
HEATER SPECIFICATIONS ................................................... 3
OPERATING PRECAUTIONS ................................................ 4
SAFETY PRECAUTIONS ....................................................... 4
ODOR FADE WARNING ........................................................ 5
OPERATING INSTRUCTIONS .............................................. 6
SERVICING ............................................................................ 7
SIZE & CAPACITY OF PROPANE CHART ............................. 7
BTU’S REQUIRED CHART .................................................... 7
REPLACEMENT PARTS LIST ................................................ 8
WARRANTY ........................................................................... 9
SERVICE AND PARTS ORDERING INFORMATION .............. 9
WARNING: RISK OF FIRE OR EXPLOSION
• Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
• Open windows.
•
DO NOT
try to light any appliance.
•
DO NOT
operate any electrical switches.
•
DO NOT
use any telephone in building. Immediately call the
local gas supplier from an outside telephone. Follow the gas
supplier’s instructions.
•
DO NOT
touch any electrical switch; do not use any phone in your
building.
• If you cannot reach your gas supplier, call the Fire Department.
SPECIFICATIONS
Type of Gas: .............................. For use with Propane Only
Gas Supply Pressure
to regulator .............................. Max: 200 psi (1380 kPa)
Min: 20 psi (138 kPa)
regulator out ............................ 10 psi (68.9 kPa)
Electrical Input: .......................... 115V, 60 Hz, 1Ø, 2a
Minimum Operating Voltage: 100V
Ignition: ...................................... Manual, piezo igntion
Primary Flame Control: .............. Thermo-Electric Safety Valve
Model: ...................................... 40FA
Rating: ....................................... 40,000 BTU/hr
(10.25 kW)
Fuel Consumption:..................... 1.85 #/hr (.84 kg/hr)
Fuel Orifice Port Size: ................. .84mm
MINIMUM CLEARANCE: From normal combustible material
Clearance DXH40FA
From floor ..................................0 ft.
From outlet ................................6 ft.
From sides ................................2 ft.
From top ....................................6 ft.
Locate 10 ft. from canvas or plastic tarpaulins or similar coverings
and secure them to prevent flapping or movement due to wind
action.
VENTILATION: Minimum openings required
Opening Opening
Heater
near floor near ceiling
Forced air (DXH40FA)..................................0.5 ft
2
.... ...........0.5 ft
2
Summary of Contents for DXH40FA