10. Turn the red plastic cap on the inverter’s positive (+) cable post 

(counterclockwise) and remove. Attach the positive slide-in 

connector at the end of the supplied red cable set into the groove 

of the positive (+) cable post. Replace the cap and turn clockwise 

to secure. Do not over-tighten.

11. Turn the black plastic cap on the inverter’s negative (–) cable 

post (counterclockwise) and remove. Attach the negative slide-in 

connector at the end of the supplied black cable set into the groove 

of the negative (–) cable post. Replace the cap and turn clockwise 

to secure. Do not over-tighten.

12. Make sure that all connections between cables and terminals are 

secure.

13. Press the power button to turn the inverter on. A beep will sound, 

the backlit LCD and the USB power/fault indicators will activate 

to indicate the inverter is operating properly and the 120 volt AC 

outlets are ready to power appliances that draw up to 1000W 

continuous and USB outlets up to 3.1A. Refer to “Power and Fault 

Indicators on the LCD Display” for an explanation of the operating 

and fault icons. If a fault icon appears, refer to the “Protective 

Features” section and the “Troubleshooting” section of this manual.

14. Test the inverter by turning it on and plugging in a 100 watt lamp 

or equipment. If the inverter is not operating properly, then rrefer 

to the “Protective Features” section and the “Troubleshooting” 

section of this manual.

CAUTIONS

• The cable and fuse sizes given here are a general recommendation. 

You should always consult your National Electrical Code prior to 

beginning each specific installation.

• Loose connectors may cause overheated wires and melted insulation.

• Check to make sure you have not reversed the polarity. Damage due 

to reversed polarity is not covered by our warranty.

Important Cable Information: 

Substantial power loss and reduced 

battery operating time results from inverters installed with cables that are 

not able to supply full power. Symptoms of low battery power can result 

from cables that are either excessively long or an insufficient gauge. 

Connection To Load

The Power Inverter is equipped with dual standard North American 

three-prong type outlets. Plug the cord from the equipment you wish 

to operate into the AC receptacle(s). Make sure the combined load 

requirement of your equipment does not exceed maximum continuous 

power.
The Power Inverter is engineered to be connected directly to standard 

electrical and electronic equipment in the manner described above. 

Do not connect the Power Inverter to household or RV AC distribution 

wiring. Do not connect the Power Inverter to any AC load circuit in 

which the neutral conductor is connected to ground (earth) or to the 

negative of the DC (battery) source.

WARNING: Do not connect to AC distribution wiring!

Operating Instructions

The two standard North American 120 volt AC outlets and three USB 

ports are ready to use once the inverter is properly connected to a 

functioning power source and the power button is turned on. They 

allow simultaneous operation of multiple devices. Simply plug the 

110/120 volt AC appliance into one of the inverter’s three-prong AC 

outlets and/or plug the USB-powered device into one of the inverter’s 

USB charging ports and operate normally.

Notes:

A.  Ensure that the wattage of all equipment simultaneously plugged 

into the inverter does not exceed 1000 watts continuous.

B.  This inverter’s USB Charging Ports does not support data 

communication. It only provides a total of 3.1A (5V each) DC 

power to an external USB-powered device.

C.  Not all mobile phones are provided with a charging cable, they 

are normally data cables which are not supported by this device 

– please check with your mobile phone manufacturer for the 

correct charging cable.

CAUTION

 – To avoid the risk of property damage:  Always connect 

the inverter to the 12 volt DC power source before plugging any devices 

into the unit.

Care and Maintenance

STORAGE

  1. Ideal storage temperature range is 0-35°C (32-104°F).
 2. Store and use the inverter in a cool, dry place with adequate 

ventilation for all-around air circulation.

  3. Avoid locations that are exposed to heating units, radiators, direct 

sunlight, or excessive humidity or dampness.

Troubleshooting

Specific AC Outlet Problems

When the 120V AC outlets are in use, the unit will monitor for the 

following fault conditions: thermal fault, low and high battery voltage 

fault, overload and short circuit (refer to the “Protective Features” 

section).

Problem

Possible Solution

If a fault condition exists 

in either of the AC outlets, 

the LCD will display the 

fault condition and the AC 

Outlets will automatically 

shut down. Should this 

occur:

A.  Disconnect all appliances from 

the unit and press the power 

button again to turn off the unit 

immediately.

B.  Allow the unit to cool down for 

several minutes.

C.  Make sure the combined rating 

of all appliance simultaneously 

plugged into the inverter does not 

exceed 1000 watts continuous.

D.  Make sure the appliance cord(s) 

and plug(s) are not damaged.

E.  Assure there is adequate 

ventilation around the unit before 

proceeding.

DXAEPI1000CA_Type2_ManualENFR_082120.indd   12-13

DXAEPI1000CA_Type2_ManualENFR_082120.indd   12-13

8/21/2020   12:58:49 PM

8/21/2020   12:58:49 PM

Summary of Contents for DXAEPI1000CA

Page 1: ...GUIDE D UTILISATION If you have questions or comments contact us Pour toute question ou tout commentaire nous contacter 1 888 394 3392 08 21 2020 DXAEPI1000CA_Type2_ManualENFR_082120 indd 32 1 DXAEPI1000CA_Type2_ManualENFR_082120 indd 32 1 8 21 2020 12 58 44 PM 8 21 2020 12 58 44 PM ...

Page 2: ...Instructions 1 Keep these instructions 2 Heed all warnings 3 Follow all instructions 4 Avoid dangerous environments Don t use the inverter in damp or wet locations Don t use the inverter in the rain or snow 5 Clean only with a dry cloth 6 Keep the inverter away from children This is not a toy 7 Store indoors When not in use inverters should be stored indoors in dry and high or locked up places out...

Page 3: ...qualified for marine applications Follow these instructions and those published by battery manufacturer and the manufacturer of any equipment you intend to use with this unit Review cautionary markings on these products and on the engine Install and operate the inverter only as described in this Instruction Manual CAUTION To reduce the risk of property damage The Power Inverter must be connected o...

Page 4: ...he high voltage DC into 120 volts 60 Hz AC Power Inverter Output Waveform The AC output waveform of this inverter is known as a modified sine wave It is a stepped waveform that has characteristics similar to the sine wave shape of utility power This type of waveform is suitable for most AC loads including linear and switching power supplies used in electronic equipment transformers and small motor...

Page 5: ...ally shut down when the unit becomes overheated Overload Short Circuit Protection The inverter will automatically shut down when an overload or short circuit occurs Refer to Power and Fault Indicators on the LCD Display for an explanation of the icons that indicate a fault condition before shutdown To restart the unit simply unplug all devices plugged into the inverter disconnect the inverter from...

Page 6: ...Check to make sure that the inverter is turned off and no flammable fumes are present in the installation area 2 Turn the red plastic cap counterclockwise on the inverter s positive cable post and remove Attach the positive connector at the end of the red battery clip cable into the groove of the positive cable post Replace the cap and turn clockwise to secure Do not over tighten 3 Connect the red...

Page 7: ...t the Power Inverter to household or RV AC distribution wiring Do not connect the Power Inverter to any AC load circuit in which the neutral conductor is connected to ground earth or to the negative of the DC battery source WARNING Do not connect to AC distribution wiring Operating Instructions The two standard North American 120 volt AC outlets and three USB ports are ready to use once the invert...

Page 8: ...plug the AC appliance Disconnect the unit from any 12 volt DC power source Check the appliance cord Accessories WARNING Since accessories other than those offered by DeWALT have not been tested with this product use of such accessories with this unit could be hazardous To reduce the risk of injury only DeWALT recommended accessories should be used with this product If you need assistance regarding...

Page 9: ...duleur de 1000 watts Le DXAEPI1000CA onduleur de 1000W par DeWalt est un onduleur 1000W DeWalt configuré pour fournir une alimentation continue sous la forme de deux prises CA de 120 volts et trois ports d alimentation USB de 5 volts pour faire fonctionner la plupart des appareils ménagers ou électroniques Directives de sécurité importantes 1 Conserver ces directives 2 Respecter tous les avertisse...

Page 10: ...onduleur en appuyant sur le bouton marche arrêt puis de le déconnecter de la source de CC lorsqu il n est pas utilisé S assurer que la tension nominale d alimentation est de 12 volts en CC Une connexion de polarité inversée grillera le fusible risque de provoquer des dommages permanents au onduleur continu alternatif et annulera la garantie Se rappeler que l onduleur ne fera pas fonctionner des ap...

Page 11: ...ement pour réduire le risque de blessures ou de dommages matériels éteindre le produit immédiatement et le débrancher du onduleur CONSERVER CES CONSIGNES POUR UTILISATION ULTÉRIEURE Composants Fig 1 Avant A Écran LCD B Ports USB C Bouton d alimentation D Indicateurs d alimentation de panne USB E Prises 120 volts CA à trois broches F Supports de montage illustrés avec œillets de protection en caout...

Page 12: ...ssance nominale Les moteurs à induction ainsi que certains téléviseurs peut exiger deux à six fois leur puissance nominale à démarrer Parce que ces onduleurs ont un sommet watt puissance nominale beaucoup de ces appareils et d outils peut être exploité en toute sécurité L équipement qui a besoin de la plus haute puissance de démarrage des pompes et compresseurs qui commencent sous charge Ce matéri...

Page 13: ...te autre surface solide pour aider à diffuser la chaleur générée Placez l onduleur le plus près possible de la source d alimentation du courant d alimentation du courant d alimentation L onduleur ne doit être utilisé que dans des endroits SECS ne pas mettre l onduleur continu alternatif en contact avec de l eau ou d autres liquides FRAIS la température ambiante idéale doit se situer entre 10 et 20...

Page 14: ...ntihoraire et retirez le Attachez le connecteur de diapositive positif à l extrémité du câble rouge fourni placé dans la rainure du poteau de câble positif Remplacez le bouchon et tournez dans le sens des aiguilles d une montre pour le fixer Ne pas trop serrer 11 Tournez le bouchon en plastique noir sur le poteau de câble négatif de l onduleur sens antihoraire et retirez le Attachez le connecteur ...

Page 15: ... endommagés E Assurez vous qu il y a une ventilation adéquate autour de l appareil avant de procéder Problèmes spécifiques de port d alimentation USB Lorsque les ports d alimentation USB sont utilisés l appareil surveille les anomalies suivantes panne thermique panne de tension de batterie basse et haute surcharge et court circuit Problème Solution possible Si une condition de défaut dans l un des...

Page 16: ...es 1 Retourner le produit au fabricant pour une réparation remplacement ou le remboursement à la discrétion du manufacturier Une preuve d achat peut être requise par le fabricant 2 Retournez le produit chez le marchand où il a été acheté afin de procéder à un échange à condition que le marchand soit un détaillant participant Les retours devraient s effectuer au cours de la période de temps spécifi...

Reviews: