Prevention of False Alarms 

The  majority  of  alarms  that  occur  are  false.  These  situations 
happen  every  day  due  to  user  error,  incorrect  installation  or 
improper maintenance of the system. False alarms will limit the 
responsiveness  to  the  system  and  become  a  general 
inconvenience.  As  the  number  of  false  alarms  increases, 
authorities have become less apt to respond to alarm systems 
due to this problem. Many of these situations can be avoided 
by following some very simple practices. 

 

• 

Ensure all users are properly trained on the operation of the 
system

 

•  Always  Disarm  the  DS600  Mobilelock  before  entering 

protected area. 

•  Lock  all  protected  doors,  windows  or  any  other  asset 

attached to a sensor. 

•  Check that motion detectors are not obstructed. Do not install 

them facing a window or near a heating/air conditioning vent. 

 

•  Check that premises are cleared and assets secured before 

Arming the system. 

•  Turn off all noise sources – radios, compressors, generators, 

heavy equipment, etc. 

•  Know how to cancel an alarm or turn off the system before activating. 

 

•  Test the system on a monthly basis to ensure proper functioning 

 

•  Check  cellular  signal,  power  supply,  and  that  sensors  are 

secured on a daily basis. 

 

Recommended Locations 

Recommended for use in enclosed areas, offices, climate 
controlled storage, and monitoring interior spaces. 

 

•  The DS610 functions best when areas being protected are 

bounded  by  solid  barriers.  Walls  and  floors  provide  good 
back- drops for detecting moving heat (infrared) sources. 

 

•  For best detection, locate the motion sensor so that intruders 

move across detection zone patterns, rather than toward or 
away from the sensor (Fig. 2). 

 

• 

Check areas for potential sources of false alarms. 

 

Remember  that  the  sensor  responds  to  quick  changes  in 
heat  patterns  within  its  coverage  pattern.  Avoid  placing  in 
direct or reflected sunlight, or near objects that can be heated 
quickly  by  sunlight.  Do  not  place  the  DS610  looking  at 
windows. Don’t place it near heating or cooling sources, like 
heater ducts or air conditioners, which might direct hot or cold 
air onto the sensor. Avoid appliances such as space heaters 
which can rapidly heat up. 

 

•  Take into consideration the normal use of the area. Are there 

bats, mice or other animals that could activate the sensor? 

 

•  Do not obstruct the coverage pattern with furniture or other 

equipment. 

 

Installing & Changing Battery 

This wireless sensor requires a non-rechargeable CR-123 3.0 
Volt Lithium battery. 

 

CAUTION:  POTENTIAL  EQUIPMENT  MALFUNCTION  OR 
FAILURE.
 

Do not touch the electronic components inside the

 

device, except the reset button and battery. 

 

TO INSTALL BATTERY 

 

angle. Pry downward on the handle of the screwdriver until 
the latch holding the cover to the housing base releases. 

 

2.  Install the battery using the polarity (+ and  -) markings on 

the  battery and equipment. Do not use  excessive force. If 
the battery does not fit, ensure that it matches the polarity 
markings (Fig. 1). 

 
3.  Press the Reset Button (B) on the device. After resetting the 

sensor (see Device Registration), replace the cover. 

 

TO CHANGE THE BATTERY 

 

CAUTION: 

Never use a damaged or worn-out battery. 

 

1.  Carefully remove the old, discharged battery. Dispose of the 

battery according to local regulations. 

2.  Install new battery using the polarity (+ and -) markings on 

the  battery and equipment. Do not use  excessive force. If 
the battery does not fit, ensure that it matches the polarity 
markings (Fig. 1). 

 
3.  Press the Reset Button (B) on the device. After resetting the 

sensor, replace the cover. 

 

Device Registration 

1.  To activate this sensor, it must first be assigned to your DS600 

Mobilelock Device. Instructions for assigning your sensor can 
be found within your online Mobilelock account. 

NOTE:

 This sensor can be assigned to only one DS600 

Mobilelock device at a time. 

 

1.  Log into your online Mobilelock account 

 
2.  Select the Mobilelock device you wish to pair this sensor to 

and go to the Configure Units page. 

3. 

Click the link titled “Manage Bluetooth” in the Sensors section. 

 
4. 

Click to “Enable” Bluetooth. 

 
5. 

After  the  Mobilelock  device’s  Bluetooth  is  confirmed 
“Enabled”, click “Add Sensor”. After the battery is installed 
in the sensor hold it close to the DS600 and click “Scan for 
available sensors”. 

 
6.  When  the  website  shows  the  sensor  click  on  it  to  confirm 

your selection. 

7. 

Then configure the sensor: Give it a name (ie: “Downstairs 
Motion”). 

8. 

Select any optional alerts desired and click “Save and Close”. 

 
9. 

Make sure the sensor is selected as “Enabled”. 

 
10. After  registration,  Arm  the  DS600  Mobilelock  and  test  the 

sensor. 

 

WALK TEST 

 

DS610 walk test mode is a feature available to help confirm the 
proper location for installation. With the cover off hold down the 
button  found  in  the  lower  left  of  the  board  until  you  hear  a 
double beep. You will likely hear more than two beeps since it 
will be detecting motion as soon as this mode is enabled. Now 
replace  the  cover  and  place  in  the  proposed  location.  Leave 
and enter the detection zone and listen for the beep. Every time 
motion  is  detected  there  will  be  a  beep  followed  by  a  1  to  2 
second mask period as the detector re-arms. This will continue 
for approximately 5 minutes. After the allotted time, the DS610 
will  sound  a  series  of  at  least  3  rapid  beeps  and  will 
automatically  leave  test  mode  and  resume  normal  operating 
mode. 

 
1. 

Using a flat screwdriver, open the housing. Insert the 
screwdriver about .25" (6mm) at the tab on the bottom of the 
unit (Fig. 3). The screwdriver will enter the slot 

at about a 45˚ 

Summary of Contents for DS610

Page 1: ...t 10 20 30 40 50 60ft 50 Top 40 View 30 20 10 0 5 10 15 m 5m 10m 15m 20m 2 1m Side 5m 10m 15m 20m View FCC REGULATORY STATEMENT FCC X8W BC832 This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 the device must accept any interference received including interference that may cause undesired op...

Page 2: ...downward on the handle of the screwdriver until the latch holding the cover to the housing base releases 2 Install the battery using the polarity and markings on the battery and equipment Do not use excessive force If the battery does not fit ensure that it matches the polarity markings Fig 1 3 Press the Reset Button B on the device After resetting the sensor see Device Registration replace the co...

Page 3: ...s been tripped 2 LED enables RED LED that will flash when motion alarm has been tripped Note switching 1 and or 2 to ON will increase battery drain and shorten battery run time Adding a Filter 3 FILTER E when ON a two phase digital filter is employed to reduce false alarms from transient electrical noise OFF removes the filter and is the most sensitive Full One Year Warranty The DeWALT Mobilelock ...

Page 4: ...erías lejos del alcance de los niños FIG 1 CUIDADO POTENCIAL MAL FUNCIONAMIENTO DE EQUIPO O FALLA No toque los componentes electrónicos dentro del dispositivo excepto el botón de reinicio y batería FIG 2 ft 10 20 30 40 50 60ft 50 Top 40 View 30 20 10 0 5 10 15 m 5m 10m 15m 20m 2 1m Side 5m 10m 15m 20m View DECLARACIÓN REGULATORIA FCC FCC X8W BC832 Este dispositivo cumple con la Parte 15 de las Reg...

Page 5: ...rca de objetos que puedan calentarse rápidamente por la luz solar No coloque el DS610 en cara hacia las ventanas No lo coloque cerca de fuentes de calor o frío como ductos de calefacción o aires acondicionados los cuales pudieran dirigir aire caliente o frío hacia el sensor Evite electrodomésticos como los calentadores de espacios los cuales se pueden calentar rápidamente Tome en consideración el ...

Page 6: ...sta Para ver la colocación de la cinta para montar vea la figura 4 Monte el sensor de 3 6 9 a 1 8m del piso Cualquier altura fuera de este rango disminuiría la sensibilidad del detector de movimiento Asegúrese de que el sensor esté seguro para que no sea golpeado o de otra manera movido Sensibilidad ajustable El DS160 viene configurado de fábrica con una sensibilidad de movimiento que es la mejor ...

Page 7: ......

Reviews: