User’s Manual Version 1.2
Devolinx Serial-Ethernet Server
STE-601C
Copyright © 2007 Aaxeon Technologies, Inc.
All rights reserved.
- 42 -
You can choose either 568A or 568B definition. If you want to make a crossover cable, you should use 568A
and 568B definition respectively in each terminal of a UTP cable.
A.3.3 Power terminal block connector
A.4 Buzzer/LED Message
A.4.1 Buzzer
“ ^ “:
Beep twice
“ = “:
Beep off
Message
Description
^===^===^===^===^===^===^...
(1sec)
Watchdog problem, return service is required
^^^^^^^^^^^^^^^^^^^^^^^...
Memory problem, return service is required
^==^========^^
(5sec)
Startup OK but AP firmware is disabled
^==^========^^^
(5sec)
Startup OK and AP firmware is enabled
Table 1. Buzzer Message
A.4.2 LAN LED
Message
Description
LED Off
No data is transmitting on Ethernet
LED blinking
Data is transmitting on Ethernet
Table 2. LAN LED Message