DEVOLA DVM1000W User Instructions Download Page 10

10

 

Caster Installation & Removal

 

 

          If the casters have been installed

 

        correctly you will hear a click sound

 

 

 
 

Specifications

 

 

 

Model Number

 

DVM1000W

 

DVM1500W

 

DVM2000W

 

DVM2400W

 

Rated Power

 

500W/1000W

 

750W/1500W

 

1000W/2000W

 

1200W/2400W

 

Rated Voltage

 

220-240V~ 50Hz

 

Dimensions(mm)

 

W460 x D107 x 

H400

 

W690 x D107 x 

H400

 

W830 x D107 x 

H400

 

W950 x D107 x 

400

 

Room 

Coverage 

(

)

 

12

 

17

 

22

 

26

 

IP Rating

 

IP24

 

Cable Length

 

1.5m

 

Clearances

 

Minimum of 1m from wall/ceiling/floor

 

Colour

 

White

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Push the button up to remove 

the caster

 

 

Summary of Contents for DVM1000W

Page 1: ...ELECTRIC CONVECTOR HEATER SLIMLINE PANEL HEATER WITH DIGITAL TIMER MODEL s DVM1000W DVM1500W DVM2000W DVM2400W User Instructions Please read and save these instructions...

Page 2: ...ot let bare skin touch hot surface Switch off and leave to cool before moving Do not use the appliance to dry clothes Do not insert or allow foreign object or metal utensils to enter any ventilation o...

Page 3: ...ce The appliance must not be located immediately below a socket outlet Do not use this appliance with another programmer timer or any other device that switches the heater on automatically since a fir...

Page 4: ...4 APPLIANCE OVERVIEW Fig 1 Circuit Diagram Air Outlet Control Panel Power Switch Castor Wheel Stand Tip over switch Heating element KSD thermostat KSD thermostat Temperature sensor Switch...

Page 5: ...lt is MON Monday The hour display 17 the minute display 16 of the time and the temperature display 15 in degrees Celsius 35 is the default You will need to set the correct time and this will then be s...

Page 6: ...of the timer to cease heating Press the up 10 and down 11 buttons to select the hour if the selected hour is prior to the current hour the system automatically rolls over to the following day 3 Press...

Page 7: ...acity 4 shows LO is deactivated In the case of partial capacity heating LO is activated on the display 4 and HI is deactivated on the display 5 Manual Mode and Auto Mode Press the M A mode selection b...

Page 8: ...for 3 seconds and the child lock is deactivated Method 2 Switch off the device using the power button 20 The unit will then enter standby mode Method 3 Turn off the power supply by pressing the power...

Page 9: ...heater in the sturdy position 2 The heater should be installed so that the controls cannot be touched by a person using a bath or shower 3 The heater should be installed so that it is not located dire...

Page 10: ...M2000W DVM2400W Rated Power 500W 1000W 750W 1500W 1000W 2000W 1200W 2400W Rated Voltage 220 240V 50Hz Dimensions mm W460 x D107 x H400 W690 x D107 x H400 W830 x D107 x H400 W950 x D107 x 400 Room Cove...

Page 11: ...no Electronic heat charge control with room and or outdoor temperature feedback no Fan assisted heat output no Type of heat output room temperature control Single stage heat output and no room tempera...

Page 12: ...uctions are excluded Consequential costs such as labour charges or damage to surroundings are expressly excluded Contact Us If you experience a problem with this product you should first contact us on...