DEVOLA DV16L Instruction Manual Download Page 2

 

Please keep this manual carefully for future reference! 

Thank you for purchasing our Devola dehumidifier. Be sure to read this manual carefully 
before using it. Any questions, please contact a professional service, or alternatively our 
customer service team for help. 

1. BEFORE YOU BEGIN

 

Please read the operating instructions carefully before using your dehumidifier for the 
first time. 

1.1 PRODUCT DESCRIPTION 

The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in 

relative humidity protects buildings and their contents from the adverse effects of excess humidity. 

The environmentally friendly R290 is used as the refrigerant. R290 has no damaging influence 

on  the  ozone  layer  (ODP),  a  negligible  greenhouse  effect  (GWP)  and  is  available  worldwide. 

Because of its efficient energy properties, R290 is highly suitable as a coolant for this application. 

Special precautions must be taken into consideration due to the coolant's high flammability. 

SYMBOLS FROM THE UNIT AND USER MANUAL 

 

warning

 

T

his unit uses a flammable refrigerant. 

If the refrigerant leaks and comes in contact with fire or 
another heating source, it will create a harmful gas and 

there is risk of fire.

 

 

Read the USER MANUAL carefully before operation. 

 

Further information is available in the USER MANUAL, 

SERVICE MANUAL, and the like. 

 

Service personnel are required to carefully read the USER 

MANUAL and SERVICE MANUAL before operation. 

 

Summary of Contents for DV16L

Page 1: ...DEHUMIDIFIER INSTRUCTION MANUAL Model s DV16L DV16LWF DV20L DV20LWF...

Page 2: ...nmentally friendly R290 is used as the refrigerant R290 has no damaging influence on the ozone layer ODP a negligible greenhouse effect GWP and is available worldwide Because of its efficient energy p...

Page 3: ...the atmosphere R 290 propane is flammable and heavier than air It collects first in low areas but can be circulated by the fans If propane gas is present or even suspected do not allow untrained pers...

Page 4: ...sconnected from its power source during maintenance Always operate the unit from a power source of equal voltage frequency and rating as indicated on the product rating label Always use a power outlet...

Page 5: ...the manufacture The appliance should be stored in a room without continuously operation sources for example open flames an operating gas appliance or an operating electric heater The appliance should...

Page 6: ...safety checks are necessary to ensure that the risk of ignition is minimized For repair to the refrigerating system the following precautions should be complied with prior to conducting work on the s...

Page 7: ...ed area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work A degree of ventilation should continue during the period tha...

Page 8: ...ures If a fault exists that could compromise safety then no electrical supply should be connected to the circuit until it is satisfactorily dealt with If the fault cannot be corrected immediately but...

Page 9: ...on Effectively removes moisture dust from the air Low power consumption energy efficient Quiet fan has two speed settings Auto Defrost at low temperature Auto shut off auto restart Electronic control...

Page 10: ...e subject to Heat sources such as radiators heat registers stoves or other products that products that produce heat In an area where oil or water may be splashed Direct sunlight Mechanical vibration o...

Page 11: ...ight for at least 24 hours before start up 8 Keep doors and windows closed for better efficiency savings 9 Do not operate or store the unit in direct sunlight or rain 10 It is normal for air outlet to...

Page 12: ...shut down after 30 seconds Mode There are three modes Auto mode continuous drying mode and a sleeping cycle mode Press once to switch the mode from one to another the corresponding indicator lights up...

Page 13: ...mode Touch the speed button to switch between high and low fan speed Up Press this button to set the humidity and timer Humidity adjusting the order of 30 to 35 40 45 50 55 60 65 70 75 80 30 To set t...

Page 14: ...We recommend disconnecting the appliance from the power supply when you are away from home to prevent unintentional switching on in your absence System Requirements for Use of the App iOS 8 0 or highe...

Page 15: ...ance by attaching a drain hose 5 3 1 EMPTYING THE WATER TANK The appliance will shutdown once the water tank has reached its full capacity The unit will only start up again when the water tank is empt...

Page 16: ...15 1 Pull out the water tank 2 Empty the water tank 3 Replace the empty tank back into the unit...

Page 17: ...ater tank is dirty please rinse it with clean water Avoid using detergents steel wire balls chemical dust removers diesel benzene diluents or other solvents These products can damage the tank and caus...

Page 18: ...f it becomes blocked it can cause damage to the unit The air filter requires regular cleaning The air filter is removable for easy cleaning Do not operate the unit without an air filter or the evapora...

Page 19: ...18 Rinse under running water or using the vacuum to clean the dust Reassemble the air filter...

Page 20: ...while moving the unit Empty the water tank before transporting the unit Check if the drain hose is kinked or bent Straighten the hose to avoid a trap existing Excessive Noise Check if the unit is secu...

Page 21: ...uctions are excluded Consequential costs such as labour charges or damage to surroundings are expressly excluded Contact Us If you experience a problem with this product you should first contact us on...

Reviews: