DS2400T DVB-T2 Signal Analysis Meter Operation Manual
86
Page three(3/4) is used for
DVB-C singles test. five limit
items list include of MIN POWER, MAX POWER, MIN
MER, MAX PRE-BER and MAX POST-BER. The default
value of these Limit items are list as Table 4-4-3.
The
difference between MAX POWER and MIN POWER
must be larger than six dB.
Table 4-4-3
Item
Limit
Minimum Power level
50
dBμV
Maximum Power level
90d
BμV
Minimum MER
32dB
Maximum PRE-BER
1.0E-7
Maximum POST-BER
1.0E-9
Page three(4/4) is used for tilt measurement, two limit
items list including of MIN TILT and MAX NOISE. The
default value of these Limit items are list as Table
4-4-4.