![DeVillbiss Air Power Company AFN5 Operation, Maintenance And Parts Manual Download Page 11](http://html1.mh-extra.com/html/devillbiss-air-power-company/afn5/afn5_operation-maintenance-and-parts-manual_2489339011.webp)
11
OPERATING THE TOOL
Disconnect tool from air compressor before adjust-
ing, clearing jams, servicing, relocating and during
non-operation.
FASTENER JAMMED IN FASTENER DISCHARGE AREA:
1. Disconnect tool from air hose.
(Step 1)
2. Pull feeder shoe back into "locked" position and
remove nails.
(Step 2)
3. Unlatch and open door.
(Step 3)
4. Grab jammed fastener with pilers and remove:
close latch door.
(Step 4)
5. Reload fasteners into magazine and unlock feeder
shoe.
FASTENER JAM INSIDE MAGAZINE:
1. Disconnect tool from air hose.
2. Pull feeder shoe back into "locked" position.
3. Remove jammed fasteners.
4. Load good fasteners and unlock feeder shoe.
Step 3
Step 2
Step 1
CLEARING A JAM FROM THE TOOL
1. Add
one drop
of Air Tool Oil, high speed spindle oil,
such as Unocal RX22, or 3-in1 oil into the air inlet.
2. Connect the Tool to the air supply.
3. Regulate the air pressure to obtain a minimum of 75 PSI
at the tool.
4. Test for proper fastener penetration by driving fasteners
into a sample piece of wood. If the fasteners do not
achieve the desired penetration, adjust the air pressure
to a lower or higher setting until the desired penetration
is achieved. Do not exceed 100 PSI at the tool.
Step 4