WARNING
Risk of injury. Equipment and fluid may be under pressure. Pressure in the system must be
relieved before beginning the cleaning procedure and before replacing any parts. Follow the
procedures in the literature provided with the system.
CLEANING
1. Relieve air pressure from pressure feed tank. Carefully follow instructions in bulletin sent with tank.
2. Replace material in container with a suitable solvent.
3. Repressurize system.
4. Trigger gun and repeat procedure until gun and hose are thoroughly clean. A SolventSaver
TM
type
hose and gun cleaner which supplies a mixture of air and solvent can be used to most effectively clean
gun and hose internal passages. See “Accessories” for SolventSaver
TM
. Wipe exterior of gun with a
solvent dampened cloth.
5. If a recirculating system is used, it may be necessary to fit a shut off valve in return line to ensure fluid
tip and forward portion of sprayhead passage are properly cleaned when flushed with solvent.
CAUTION
Do not totally submerge gun in solvent. It is possible to wash solids into air operating sections of
gun which could seriously damage piston “O” Ring seals.
CAUTION
The air cap can be immersed in solvent for cleaning. If orifices are clogged, use a broom straw or
toothpick to remove obstruction. Never use a steel wire or hard instrument. This will damage air
cap and result in a distorted spray pattern.
REPLACEMENT
Tools Required
•
Crescent Wrench
•
1/2 Box Wrench (for Item No. 3)
•
Pliers (for Needle Assy)
•
3, 6, 13, 14mm Open Wrench (for Item No. 12, 17, 1, 5)
•
1.5mm Hex Wrench (for Item No. 16)
•
T-AGB-GRT-1 (for Item no. 7)
•
T-AGB-HW-1 (for Item No. 11)
-
5
-