background image

3 — ENG

LIMITED WARRANTY

ONE YEAR FROM DATE OF PURCHASE

All merchandise manufactured by DeVilbiss Air Power Company is warranted to be free of defects in workmanship
and material which occur during the first year from the date of purchase by the original purchaser (initial user). Products
covered under this warranty include: air compressors, *air tools, accessories, service parts, pressure washers, and
generators used in consumer applications (i.e., personal residential household usage only).

Air compressors, *air tools, accessories, service parts, pressure washers, and generators used in commercial
applications (income producing) are covered by a 90 day warranty.

DeVilbiss Air Power will repair or replace, at DeVilbiss's option, products or components which have failed within the
warranty period. Repair or replacement, and service calls on 60 and 80 gallon air compressors, will be handled by
Authorized Warranty Service Centers and will be scheduled and serviced according to the normal work flow and
business hours at the service center location, and depending on the availability of replacement parts.

All decisions of DeVilbiss Air Power Company with regard to this policy shall be final.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

RESPONSIBILITY OF ORIGINAL PURCHASER (Initial User):

THIS WARRANTY DOES NOT COVER:

DeVilbiss Air Power Company

213 Industrial Drive • Jackson, TN 38301-9615 • Telephone:  1-800-888-2468 , Ext. 2 •  FAX:  1-800-888-9036

Retain original cash register sales receipt as proof of purchase for warranty work.

Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s).

Deliver or ship the product  to the nearest  DeVilbiss Air Power Authorized Warranty  Service Center.
Freight  costs, if any, must be paid by the purchaser.

Air compressors with 60 and 80 gallon tanks only will be inspected at the  site  of  installation. Contact the nearest
Authorized Warranty Service Center, that  provides on-site service calls, for service call arrangement.

If  the  purchaser does not receive satisfactory results from the Authorized Warranty Service Center, the purchaser
should contact DeVilbiss Air Power Company.

Merchandise sold as reconditioned, floor models and/or display models. Any damaged or incomplete equipment
sold "as is".

Merchandise used as "rental" equipment.

Merchandise that has become inoperative because of ordinary wear, misuse, freeze damage, use of  improper
chemicals, negligence, accident, improper and/or unauthorized repair or alterations including  failure to operate
the product in accordance with the instructions provided in the Owners Manual (s) supplied with the product.
*Air Tools: O-Rings and driver blades are considered ordinary wear parts, therefore, they are warranted for a
period of 45 days from the date of purchase.

An air compressor that  pumps air more than 50% during a one hour  period is considered misuse because
the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is
30 minutes.

Merchandise sold by DeVilbiss Air Power which has been manufactured by and identified as the  product of
another company. The product manufacturer's warranty will apply.

Repair and transportation costs of merchandise determined not to be defective.

Cost associated with assembly, required oil, adjustments or other installation and start-up cost.

ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE,  OR  EXPENSE THAT MAY RESULT FROM
ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. 

 Some states  do not allow the exclusion or limitation

of incidental or consequential damages, so the above limitation or exclusion may not  apply to you.

IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE.  

Some states do not  allow

limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

Form: SP-100-E - 4/25/96

Summary of Contents for FAC100-1

Page 1: ...LOSS OF LIFE Information that you should pay special attention to URGENT SAFETY INFORMATION A HAZ ARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE This manual contains information that is important...

Page 2: ...5 DUTYCYCLE 5 DESCRIPTIONOFOPERATION 6 INSTALLATIONANDBREAK IN PROCEDURES 6 7 LocationofAirCompressor 6 Page ExtensionCords 6 GroundingInstructions 6 7 AirHose 7 OPERATINGPROCEDURES 7 STORAGE 8 AIRCO...

Page 3: ...t the site of installation Contact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangement If the purchaser does not receive satisfactory result...

Page 4: ...FROM ELECTROCU TION SEE GROUNDING INSTRUCTIONS FOLLOW THE EQUIPMENT MANUFACTUR ERS RECOMMENDATION AND NEVER EX CEED THE MAXIMUM ALLOWABLE PRES SURE RATING OF ATTACHMENTS NEVER USE COMPRESSOR TO INFLAT...

Page 5: ...OSE YOU TO MOVING PARTS AND ELECTRICAL SHOCK A PORTABLE COMPRESSOR CAN FALL FROM A TABLE WORKBENCH OR ROOF CAUSING DAMAGE TO THE COMPRESSOR WHICH COULD EXPOSE YOU TO HAZARD OUS MOVING OR ELECTRICAL PA...

Page 6: ...or blow off dust or dirt that collects on the air compressor A clean air compressor runs cooler and provideslongerservice Theventilationopeningsonyour aircompressorarenecessary tomaintainproper operat...

Page 7: ...sor settheadjust able pressure valve to 10 PSI Make sure the ON OFF switch is in the OFF position 2 Connect the air tool or accessory to the air hose Tightensecurely 3 Plug the power cord into the gro...

Page 8: ...o OFF and unplug the cord 2 Relieve all pressure from the air compressor head andairhosebysettingtheadjustablepressurevalve to 10 P S I 3 Protecttheelectricalcordandairhosefromdamage bywindingthemloos...

Page 9: ...9 ENG AIR COMPRESSOR DIAGRAM...

Page 10: ...d gasket Valve plate assembly O ring Outlet tube Rod assembly Screw 3 8 16 x 1 25 LG hex socket flat head Cylinder sleeve Endbell assembly Timing belt Pump isolator Shroud right Switch Housing isolato...

Page 11: ...be using a Quick Acting fuse 3 Check for low voltage problem 4 Check the extension cord 5 Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Fu...

Page 12: ...dering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following information Model number of your product Part number and des...