IMPORTANT: Read and follow all INSTRUC-

TIONS and SAFETY PRECAUTIONS before 

installing,  operating or maintaining this 

equipment. Keep this manual for future 

reference.

DESCRIPTION

The  DAD-503 is designed to be a point 

of use system. It is capable of removing 

dirt, water, oil and water vapor hydrocar-

bons and odors from compresssed air. It 

consists of a filter separator, coalescing 

filter, charcoal filter, flow thru regulator, 

desiccant dryer, air regulator, and main 

air supply shut off valve.  

A clean filtered supply of air must be  

provided for use with a supplied air  

respirator.  In addition, air for spray  

operations passes through the desiccant 

filled tank that removes any remain-

ing water vapor to a -40° F Dew Point,  

providing the ultimate air supply for spray 

finish applications.

SPECIFICATIONS

Air Filter (Separator):

Air Inlet 

 

1/2" NPT(F)

Air Outlet   

1/2" NPT(F)

Air Flow Capacity 

100 CFM

Maximum Operating Press. 

150 PSIG (10.3 Bar)  

Maximum Temperature 

150° F (65.6°C)

Automatic Mechanical Drain   Supplied

Filter 

 

5 micron

Coalescing Filter:

Air Inlet 

 

1/2" NPT(F)

Air Outlet   

1/2" NPT(F)

Air Flow Capacity 

55 CFM

Maximum Operating Press. 

150 PSIG (10.3 Bar)

Maximum Temperature 

150° F (65.6°C)

Automatic Mechanical Drain    Standard

Pressure Differential Ind.  

Standard

Filter  

 

0.01   Micron

Charcoal Filter:

Air Inlet 

 

1/2" NPT(F)

Air Outlet   

1/2" NPT(F)

Air Flow Capacity 

75 CFM

Maximum Operating Pressure  150 PSIG (10.3 Bar)

Maximum Temperature 

150° F (65.6°C)

Manual Mechanical Drain  

Standard

Pressure Differential Indicator  Standard

Aerosol Filter  

.003 ppm./wt.

Particulate Filter 

3.0 micron

Flow Thru Regulator:

Flow Thru Ports 

1/2" NPT(F)

Regulated Ports 

1/4" NPT(F)

Air Flow Capacity(regulated)  28 CFM @ 60 PSI

   with 100 PSI Inlet

Maximum Inlet Pressure 

300 PSIG

Regulated Pressure 

0-125 PSIG

Maximum Temperature 

175° F (79.4°C)

Desiccant Dryer:

Air Inlet 

 

1/2" NPT(F)

Air Outlet   

1/2" NPT(F)

Air Flow Capacity 

25 CFM

Maximum Operating Pressure  150 PSIG (10.3 Bar)

Maximum Temperature 

150° F (65.6°C)

Humidity Indicator 

Standard

Water Vapor Removal 

-40° F Dew Point

Tool Air Regulator:

Air Inlet 

 

3/8" NPT(F)

Air Outlet   

1/4" NPT(F) (3 ea.)

Air Flow    

 60 CFM

Maximum Operating Pressure  150 PSIG (10.3 Bar)

Maximum Temperature 

120° F (48.9°C)

VA-595 Main Air Supply Shut Off Valve:

Air Inlet and Air Outlet 

1/2" NPT(M)

Maximum Operating Pressure  175 PSIG (12.0 Bar)

BREAThINg AIR REqUIREMENTS

Supplied breathing air, as defined by 

OSHA 29 CFR 1910.134i and NIOSH 42 CFR 

84.141, MUST meet or exceed the following  

requirements for Type 1-Grade D breath-

able air, as defined in Compressed Gas 

Association (CGA-G7-1-1997):

Oxygen = 19.5-23.5% (Typical  

atmospheric levels)
Oil (condensed) = 5 mg/m (mil-

ligrams per cubic meter) maximum
Carbon Monoxide (CO) = 10 ppm 

(parts per million) max.
Carbon Dioxide (CO

2

) = 1OOO ppm 

(parts per million) max. (Typical  

atmospheric levels)
Odor = The presence of a pro-

nounced odor should render the  

air as unsatisfactory

It is up to the employer to assure that the 

air compressor is properly maintained, 

that the air compressor intake is located  

in a clean contaminate free location  

and that the air compressor is drawing 

in typical atmospheric air, meeting all of 

the national and local requirements for 

breathing air.

This filter unit does not remove or filter 

Carbon Monoxide (CO). It is up to the 

employer to ensure that the level of CO 

does not exceed the maximum national 

or local allowed level. The recommended 

method to assure that the CO level is not 

exceeded is to install a carbon monoxide 

monitor and alarm.

SB-6-159-h

Replaces SB-6-159-G

SERVICE BULLETIN

DAD-503  (130089) AIR STATION WITH DESICCANT

This filter unit will only remove particulate 

matter, water, oil and odor. This filter unit 

will meet the particulate matter, oil and 

odor requirements of Type 1-Grade D 

Breathable Air and Compressed Breathing 

Air, CSA-Z180.1 when:

•  The  filter  unit  is  connected  to  a   

compressed air source:

 The compressor is properly 

maintained

 The air compressor intake is 

located in a clean contaminate 

free location

 The air compressor is draw-

ing in typical atmospheric air, 

meeting all of the national  

and local requirements for 

breathing air

• The filters are properly maintained

• A properly operating CO monitor 

is installed

Risk of explosion or fire.

Improper use can cause  

personal injury.

•  This  product  is  designed  and   
intended for use in industrial com-
pressed air systems only.  Do not use 
for liquids or gasses other than air.

• Do not use where pressure or tem-
perature can exceed rated operating 
conditions (see specifications).

•    Regulated  outlet  pressure  must 
never be set higher than the  
maximum operating pressure of the 
downstream air tool or equipment.  
An outlet pressure gauge should  
always be used.

Risk of illness or death. Carbon  
monoxide can cause nausea,  
fainting or death. Stop using if car-
bon monoxide is present. This unit 
does not remove carbon monoxide.  
A carbon monoxide monitor should  
be incorporated into your air sup-
ply line to warn of the presence of  
carbon monoxide.

Summary of Contents for DAD-503

Page 1: ...defined by OSHA29CFR1910 134iandNIOSH42CFR 84 141 MUSTmeetorexceedthefollowing requirements for Type 1 Grade D breath able air as defined in Compressed Gas Association CGA G7 1 1997 Oxygen 19 5 23 5...

Page 2: ...njury Release all air pressure from systembeforeservicingsystem Be sure to read and understand all Service Bulletins on the separate components before using the system Use only specified DeVilbiss par...

Page 3: ...26 Baffle Included with HAF 26 HAF 17 Bowl O Ring Body Not Available Figure 3 13 0041 HAF 11 Flexible Drain supplied with 13 0041 HAF 19 Metal Bowl Guard OPERATION After the system is installed and r...

Page 4: ...erforming maintenance on unit close any main shut off valve located upstream of filter Bleed off residual air in unit 2 To open filter press button located on clamp ring and rotate ring either clockwi...

Page 5: ...nd the relief seat for dam age and contamination Replace dia phragm assembly if necessary Clean the relief seat with a soft dry cloth Reassemble in reverse order making sure the slip ring is properly...

Page 6: ...de See Figure 9 4 Using a knife edge carefully pry off flat cap See Figure 10 Pry apart with knife edge 5 Clean inside of flat Remove all traces of water or dirt 6 Insure rubber seal is in place in th...

Page 7: ...Use a 4 Phillips screwdriver and reverse the above procedures to install a new DAD 8 filter Install about halfway into the tank fitting 16 Reverse procedure to reassemble Refill with desiccant DAD 8 R...

Page 8: ...s through the pipe This water a problem in itself also can cause scaling and rust inside the piping The backward sloping of the pipe helps drain these contaminates back toward the compressor drain whi...