background image

Page 9

SB-2-548-A

ACCESSORIES

These brushes are
helpful in cleaning
threads and recesses
of gun body.

42884-214-K5 3/8"

42884-215-K10 5/8"

Cleaning Brushes

HAV-500 does not
have pressure gage.
Use to control air
usage at gun.

HAV-500  or

HAV-501

Adjusting Valve

(HAV-501 SHOWN)

Removes water, oil,
and debris from the air
line.

HAF-507 

Whirlwind™

In-Line Air Filter

2 Gallon galvanized
tank used to clean the
inside of hose and
material passages of
the gun.

For trapping foreign
particles in the paint
supply.

2 Qt Hose/Gun Cleaner
used to clean the
inside of hose, fluid
passageways of gun &
other paint equipment. 

Compatible with all
paint materials:
contains no silicone or
petroleum distillates to
contaminate paint.
MSDS sheet available
upon request.

Spray Gun Lube

SSL-10 (2 oz.

bottle) 

Installs into gun to
enable user to control
and reduce air usage
at the gun. Replaces
SP-637 plug.

SP-402-K Air

Adjusting Valve

QMGZ

SolventSaver™

Hose/Gun Cleaner

PLH-MF-6-100 

Mini-Strainer 

(100 mesh)

Digital pressure
gauge for precise
pressure control at
the gun.

DGI-501-PSI-USA

Digital 

Pressure Gauge

TGC-545

Aluminum 1-Qt. 

Suction Cup

HD-503

SolventSaver™

Hose/Gun Cleaner

P-H-5516 Air

Adjusting Valve

Enables user to control
and reduce air usage
at the gun. Ideal for
low pressure spraying.

HC-4700

1/4" NPT(F)

HC-1166

1/4" NPT(M)

HC-4699

1/4" NPT(M)

HC-4419 1/4" 

NPS(F)

Quick Disconnect Approved for

HVLP Guns (Air)

High Flow Ball and Ring Type

1 Qt. pressure feed cups. 
3/8" NPS (F), cam lock lid. 
Requires KK-4980 air regu-
lator kit.

TLC-576 Aluminum Cup

(Teflon Lined) &  

TSC-591Stainless Steel Cup

KB-555 (Aluminum) & 

KB-545-SS (S/S) 2 qt. Pressure

Feed Cup With Regulator

Millennium 3000

Twin Cartridge 

Paint Spray Respirator

Provides greater
degree of control
over cup fluid pres-
sure.

NIOSH-Certified, for 
respiratory protection 
in atmospheres not 
i m m e d i a t e l y
dangerous to life.

Use to maintain nearly
constant outlet pres-
sure despite changes
in inlet pressure and
downstream flow.

HARG-510  Air

Regulator

Contains all necessary
tip, hose and nut sizes
used on or with gun.

SPN-5 

Wrench

Scrubs

®

are a pre-

moistened hand cleaner
towel for painters. No
water is needed.

29-3100 Scrubs

®

Hand Cleaner

Towels

Fits Compact gun only. 

Compatible with DeVilbiss

high flow quick disconnects.

MPV-60-K3

Air Inlet Swivel

(Pack of 3)

Compatible with

SP-200S-08-K (0.55 mm) and

SP-200S-10-K (1.0 mm) fluid nozzles

SP-300P-10-K

Plastic Tipped Fluid Needle

Summary of Contents for Compact COM-PS430-18-01

Page 1: ...ces SB 2 548 OPERATION MANUAL ADVANCED CONVENTIONAL PRESSURE FEED SUCTION FEED SPRAYGUN English Pages 2 9 MANUAL DE OPERACI N PISTOLA PULVERIZADORA CON ALIMENTACI N POR PRESI N POR SUCCI N AVANZADA CO...

Page 2: ...alogenated Hydrocarbons Static Electricity can be generated by fluid and or air passing through hoses by the spraying process and by cleaning non conductive parts with cloths To prevent ignition sourc...

Page 3: ...using seal SP 612 K 1 11 Spindle 1 12 Trigger SP 617 K 1 13 Connector SP 611 K 1 14 Plug SP 637 1 15 Fluid Inlet Connector and seal SP 636 K 1 16 Air Valve Service Kit SPK 101 K 1 17 Retaining Ring an...

Page 4: ...ys turn off air and fluid supply and relieve pressure when gun is not in use PREVENTATIVE MAINTENANCE 1 Turn off air and coating supply and relieve pressure in the supply lines or if using QD system d...

Page 5: ...g Service Tool SPN 7 engage groove behind the Valve Seat 6 Remove Valve Seat 7 Push out the Front Airvalve Seal with a finger 8 Turn the Gun upside down and let the Seal fall out 9 Fit New Front Seal...

Page 6: ...ment 14 Fit new Seal to Service Tool 15 Fit Seal to Housing 10 16 Replace Valve 11 17 Replace Valve Spring and screw in Housing 10 18 Tighten Housing 19 Fit Needle 9 20 Fit Spring 8 and Knob 7 21 Adju...

Page 7: ...loose fluid needle packing nut Lubricate or tighten Unable to get round spray Spreader adjustment screw not seating properly Clean or replace Air cap retaining ring loose Tighten Will not spray No air...

Page 8: ...onal Compact Gun 98 3151 1 2 Diaphragm Pump Outfit 5 gal Pail Mount with Advanced Conventional Compact Gun 98 3154 80 295 Aluminum 2qt Cup Outfit with Advanced Conventional Compact Gun TROUBLESHOOTING...

Page 9: ...t Suction Cup HD 503 SolventSaver Hose Gun Cleaner P H 5516 Air Adjusting Valve Enables user to control and reduce air usage at the gun Ideal for low pressure spraying HC 4700 1 4 NPT F HC 1166 1 4 NP...

Page 10: ...enerada por el paso de fluido y o aire por los manguitos por el proceso de pulverizaci n y por la limpieza de piezas no conductoras con pa os Para impedir que las descargas est ticas produzcan fuentes...

Page 11: ...611 K 1 14 Tap n SP 637 1 15 Entrada de fluido Conector y junta SP 636 K 1 16 Kit de mantenimiento de la SPK 101 K 1 v lvula de aire 17 Ret n y juntas SPK 102 K 1 18 Kit de clip junta y perno GTI 428...

Page 12: ...el 50 como m nimo Mueva la pistola a una velocidad constante 12 Cierre siempre el suministro de aire y fluido y alivie la presi n cuando la pistola no se est utilizando MANTENIMIENTO PREVENTIVO 1 Cier...

Page 13: ...o de la v lvula 6 Retire el asiento de la v lvula 7 Haga salir la junta delantera de la v lvula de aire empu jando con el dedo 8 Ponga la pistola boca abajo y deje que se caiga la junta 9 Instale una...

Page 14: ...nta de manten imiento 15 Coloque la junta en el alojamiento 10 16 Vuelva a colocar el husillo 11 17 Vuelva a colocar el muelle de la v lvula y el tornillo en el alojamiento 10 18 Apriete el alojamient...

Page 15: ...luido en el tanque Abra el tornillo de ajuste de la aguja de fluido Diluya el material o cambie a alimentaci n por presi n Sobrepulverizaci n excesiva Demasiada presi n de aire de atomizaci n La pisto...

Page 16: ...ial Superficie spera aceitosa o sucia COM PS430 18 01 Pistola alimentada por sif n con cubeta de aluminio TGC 545 de 1 cuarto de gal n COM PS430 22 01 Pistola alimentada por sif n con cubeta de alumin...

Page 17: ...y reducir el uso del aire en la pistola Ideal para pulver izaci n con presi n baja HC 4700 de 1 4 de pulg NPT F HC 1166 1 4 de pulg NPT M HC 4699 1 4 de pulg NPT M HC 4419 de 1 4 de pulg NPS F Dispos...

Page 18: ...Page 18 SB 2 548 A NOTES...

Page 19: ...P gina 19 SB 2 548 A NOTAS...

Page 20: ...U S Canada Technical Service Office 195 Internationale Blvd Glendale Heights IL 60139 Toll Free Telephone 1 888 992 4657 U S A and Canada only Toll Free Fax 1 800 368 8401 DeVilbiss Worldwide Sales a...

Reviews: