2.5 Timer Setup
The timer feature helps you programming an unlimited number of Heating Periods where the ther-
mostat will bring the temperature up the heating temperature, as well as Setback Periods when the
thermostat will bring down the temperature to the setback temperature.
2.5.1 Heating and Setback Settings
The heating temperature is the desired temperature when you want your heating system to be on.
The setback temperature is the temperature for down periods. You have two options:
1
You prefer your system to be ON or OFF. In this case, set the setback temperature to the mini-
mum allowed value (usually 5°C)
OR
2
You prefer heating system to switch between up or down periods. In this case, your heating
system is always ON. This may be a good option for slow heating systems (i.e. in-slab hydron-
ic floor heating) or for situations when you do not want to turn off your heating system (i.e. to
keep moisture out of the air).
2.5.2 Heating and Setback Temperatures Setup
Note:
When the TS 500 is regulating the floor, you actually set up the temperature of the floor, not
of the air. For that reason, temperatures can easily reach 27°C – 30°C.
2.5.3 Heating Period Setup
An unlimited number of heating periods can be set up for the different days of the week.
1
Touch the
thermostat
display to ac-
tivate it, then
press
Timer.
27.0°
Menu
Timer
2
Press
Heating
Periods.
Timer
On / Off
Temperatures
Heating Periods
ON
1
Touch the
thermostat
display to
activate it, then
press
Timer.
2
Press
Temperature.
Timer
On / Off
Temperatures
Heating Periods
ON
3
Press
Heating Tem-
perature
or
Setback
Temperature
.
4
Setup the desired
temperature for each
by using the arrows.
Press
OK
to confirm.
Temperatures
Heating Temperature
22.0
˚
Setback Temperature
5.0
˚
5
To return to the home
page press .