FrameMaker Ver.5.5E(PC) Di250 DIS/REASSEMBLY, ADJUSTMENT
99.01.07
D-38
Requirement
NOTE
This adjustment must be made when the PH Unit has been replaced and, for 2-sided, after
Registration (CD) (Printer) for each paper source for 1-sided and Registration (FD) (Printer)
have been made.
Adjustment Procedure
1. Produce a test pattern. (For details, see 3-4. TEST PRINT.)
2. 1-Sided: Check to see if width A on the test pattern meets the specifications.
2-Sided: Using the test pattern output as the original, make an ordinary 2-sided copy.
Check to see if width A on the second side of the 2-sided copy meets the
specifications.
If width A falls outside the specified range, perform these steps to make the adjustment.
(5) Registration (CD) (Printer)
Specification
Adjust Mode
Setting Range
1-Sided: 10 ±2.0 mm
2-Sided: 10 ±3.0 mm
Registration (CD)
-4.0 to +4.0
Adjust so that width A on the test pattern output falls
within the following range.
1171D006AA
A