Devatec AC4 Instructions For Use Download Page 3

 3 

**Operation**

WARNING

 : designed for atomizing water only !!!  Don’t use in any case flammable, toxic or corrosive liquids. 

x

Operating the unit with the fogging head will provide directionnal fogging output and a drier fog. 

x

For a maximum fogging and circulation, operate unit without the lower housing as well as upper housing and fogging 
head. Fog will propel from 35 to 50 cm above unit. 

**Troubleshooting**

*No Fog*

  

Check for motor rotation. If the motor is operating properly, check for an adequat amount of water in the pan (1 

to 3 cm). If the pan runs dry, the float valve may be sticking in the up position. If so, the inlet water pressure must be 
reduced. If the water supply is adequat, check the  tapered pump for internal calcium build-up. Remove, inspect and  
clean as needed. 

*Overflowing Pan*

 

An overfilled pan can cause poor quality of fog and wetness around the unit. A leaky float valve or a float that has 

filled with water may be the problem. To check the float, raise it out of the water and visually inspect it. No water 
should be inside and it should not sink. If OK, then check for a leaky valve. Turn water off and remove the fogger from 
the pan. Empty the pan and towel dry. Hold the float in the up position and turn the water on.  If the water fills the pan 
while the float is in the up position, the float valve needs being replaced. 

**Maintenance**

x

Check and clean atomizing screen and filter  

x

Regularly clean the reservoir pan assembly with soap and water to remove dirt and sediment. Use liquid bleach
after cleaning to sterilize any parts. 

x

Periodically remove strainer screen and thoroughly flush with water. Also check to make sure the pump assembly is 
free of debris. 

x

Every three months, check units for calcium build-up. If build-up deposits are present, disconnect the water and 
take the unit outside. Pour calcium dissolving solvent (available in local hardware stores) in pan and operate unit 
outside to soften and remove the deposits. 

x

On a yearly basis, remove the housing to check the SST Atomizing Screen to be sure the slots are clear of mineral 
build-up. To clean, scrub with calcium dissolving solvent. 

Summary of Contents for AC4

Page 1: ...ws to humidify and cool at the same time It can be easily installed on a level surface All these features with simple and robust construction make this humidifier ideal for a variety of applications Description Specifications Dimensions 310x310x480 mm Weight 7Kg Power supply 230V 50Hz Power consumption 70W Humidity capacity Up to 4 5l h Coverage 100 150m Colour White ...

Page 2: ...ittle to no ventilation place the unit in a central position In a ventilated area place unit near the intake end Then connect a water supply to a 6mm female inlet Power connection Plug the unit directly into an electrical outlet for evaluation Listen for a smooth quiet operation Motor shaft should be centered and vertical Make any necessary adjustments After evaluation connect AC4 to desired contr...

Page 3: ... raise it out of the water and visually inspect it No water should be inside and it should not sink If OK then check for a leaky valve Turn water off and remove the fogger from the pan Empty the pan and towel dry Hold the float in the up position and turn the water on If the water fills the pan while the float is in the up position the float valve needs being replaced Maintenance x Check and clean...

Page 4: ...n 3023 Hub Assembly 3033 Handle 3024 Disk 3034 Housing 3025 Pump 3035 Float Valve 3026 Fan Blade 3036 Float 3027 Mid Pan 3037 Reservoir Pan Rue Feu St Eloi 76550 Ambrumesnil France Export Division tel 33 0 2 35 83 06 44 ou 33 0 2 35 83 03 86 Division france tel 02 35 04 61 41 fax 33 0 2 35 85 36 72 fax 33 0 2 35 85 36 72 Email france devatec com www devatec com Email export devatec com www devatec...

Reviews: