65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 22 -
FULL-DUPLEX
Full-Duplex Connection
Mode
– Select Server or Client mode of operation. For Full-duplex to be used one DB910
must be a Server and the other a Client
GPIO & COM
– Select GPIO and RS-232 passthrough mode. The corresponding GPIO
pins and RS-232 must be configured in GPIO Setting
Port
– Select Full-duplex UDP port. It is also used by the Client DB910 to connect to.
URL
– Enter URL (IP address and port) of the server DB910. This field is used in Client
mode only.
Full-Duplex TX
Input
– Select Full-duplex TX audio source: Analog Input, Digital Input or Analog Output
Loopback.
Encoder
– Select Full-duplex TX encoder. The same CODEC must be set in Full-duplex RX
of the other unit.
Full-Duplex RX
Decoder
– Select Full-duplex RX decoder. The same CODEC must be set in Full-duplex TX
of the other unit.
Gain
– audio gain adjustment. The Gain adjust is digital and if the sum of signal level and
the Gain is greater than 0dBFs the signal will be distorted;
Pre-buffer
– Set audio pre-buffer. Larger setting ensures a more stable connection in expense
of increased audio delay.