Installation and Interconnections
Before connecting the AC Power, make certain that the internal Power Switch and the fuse
rating are in accordance with the mains supply at your location.
ATTENTION:
DB8000 Power Supply Factory Settings are:
- 220 VAC
- 1-Amp fuse
CAUTION:
permanent damage will result if improper AC supply voltage is applied to the
DB8000 device. Your warranty does not cover damage caused by applying improper supply
voltage, or use of an improper fuse.
Changing AC Input Voltage Selection requires only a screwdriver and is not difficult (see
below), but you should make sure the power supply is set up correctly before connecting power.
AC INPUT VOLTAGE SELECTION
- Disconnect the AC power cable from the AC outlet.
- Disconnect all cables from the DB8000’s rear panel.
- Remove the two screws from each side of the DB8000, and the three screws from the top edge
of the rear panel. Slide the top cover towards the rear, mindful not to damage the XLR connectors
on the rear panel and then remove the cover.
- Locate the Voltage Selector Switch. It is a clearly marked slide switch next to the IEC-320
power cable connector. Move it to the “115” position for operation from 100 – 120 VAC, or to the
“230” position for operation from 200 – 240 VAC.
- Locate the fuseholder (next to the Power Switch) and replace the fuse (
if needed
). Always use
fuses with the following ratings:
•
1-Amp for 220 VAC mains voltage;
•
2-Amp for 110 VAC mains voltage;
- Replace the top cover and its seven screws.