Service
- Name – preset alias. The same name will appear on the quick access buttons in the “dashboard”;
- [Enabled]/[Disabled] channel monitoring and sending of warnings and alarms. If the channel
is not generally enabled, the frequency will not be monitored and alarm notifications will not be
received;
- Service – select the desired service from the drop-down menu;
- Acquisition time – specify the observation time for the current station (before switching to the
next channel);
- E-mail – set email address that will receive alarm notifications for this service only.
Alarm
- Alarm Range – interactive slider used to adjust the Low & High thresholds at which an alarm
will be generated;
- Warning Range – interactive slider used to adjust the Low & High thresholds at which a
warning will be generated;
- Threshold –buttons to enable/disable alarm range limits;
- Trigger Time – waiting time before Active Alarm/Warning is generated;
- Release Time – waiting time before Idle Alarm/Warning is generated;
- Alarm notification option.
IMPORTANT NOTE:
Warnings and Alarms are generated only when the Logger mode is
running. While there is any user interaction, alarm will not be generated and send. The Logger
starts running once the user logs out of the WEB interface.
Trigger and Release times define the time, which should elapse in order for the received signal
to be defined as low/high/lost or restored/OK. What we recommend is the release time to be bigger
than the trigger time.
NOTE:
When setting Trigger and Release times, have in mind that 01:00 means 1 minute, and
00:01 means 1 second.
NOTE:
In order for the applied settings to be used press the [Save] button, placed on the
bottom right part of the screen.
[Export] will export the currently applied alarms settings.
[Import] allows you to import the Service settings from other DB7012.