MONITORING
This menu pages allow you configure Logger Services. There is submenu page for each Channel
containing Service Settings. For more information of Logger and Services please refer to
“Logger Service Settings” on page 46
Alarms is a special parameter type with its own dialog editor. Each alarm parameter is composed
of the following sub-parameters:
•
Alarm Low threshold
– the lower alarm limit of the measured signal. If the value stays
below this limit for predefined time “low alarm” event will be generated;
•
Alarm High threshold
– the higher alarm limit of the measured signal. If the value stays
above this limit for predefined time “high alarm” event will be generated;
•
Warning Low threshold
– the lower warning limit of the measured signal. If the value
stays below this limit for predefined time “warning low” event will be generated;
•
Warning High threshold
– the higher warning limit of the measured signal. If the value
stays above this limit for predefined time “warning high” event will be generated;
•
Trigger time
– waiting time before a “low alarm” or “high alarm” event is generated;
•
Release time
– waiting time before an “Idle alarm” event is generated;
•
Set of notification channels
– In case of alarm, maintenance staff will be immediately
alerted via E-mail, SNMP or GPO, which allows technicians to restore the normal service
as soon as possible.