This Quick user guide will make the installation of 

DB

64-FM 

quick and easy

. Applying

 these principles, 

yo

ca

simplify the

 

process

 

and

 

save

 

yourself

 

extra time

 

and effort

For more information about the 

Safety precautions and the Operating environment recommendations please refer to the User 
Manual

.

Connection

STEP 1

1.

Install the unit on its operation place;

2. In order for the proper work of DB64-FM to be guaranteed, and due to the variability of the signal 

levels, the right reference levels of the digital and analog inputs should be set. For further information, 
please refer to the complete user manual.

3.

Before connecting the AC Power, make 

sure

 that the fuse rating is in accordance with the mains 

supply at your location. DB

64-FM 

 Power Supply Factory Settings are: 100-240

 

V

 

AC;

 

1A Fuse; 

4.

C

onfigure the DB64-FM in the proper connection configuration. For further information on the most 

common use, please refer to 

Step 2

5.

I

f need be, change the default factory preset with the one preferred. This can be made via the front 

panel menu or WEB Interface. 

?

Via front panel - press 

Soft button 4 

(from the left to the right), then using the UP and DOWN buttons 

select the preferred preset;

?

Via the WEB interface (for further information on how to access the device via WEB, refer to 

Step 3

)  

- connect the device as an administrator, select "Presets" menu, and select the preferred audio preset. 

For further information on how to create your own audio preset, or how to set up the Dayprting function, 
please refer to the complete user manual. 

The  DB64-FM  supports  several  types  of  configuration  connections,  depending  on  the  client's 
preferences.  The  two  basic  connections  are  described  in  details  below. 

For  the  other  available 

configurations, please refer to the complete user manual - www.devabroadcast.com/downloads

Configuration

STEP 2

Analog Program

STEP 2.1

DB6

4

-

FM

 is fed with analog audio. The main program 

output is sent to the DB6

4

-

FM

 Audio Processor via XLR 

Connection.  The  MPX  composite  output  is  sent  via 
BNC  connection  to  the  transmitter  MPX  input.  The 
audio processor output is MPX OUT -1.

DB64-FM – Broadcast Audio Processor

Control Room

ON AIR

BROADCAST CONSOLE

Analog Audio

Output Left-Right

Analog Audio

Input Left-Right

RF Power out for Antenna

MPX IN

FM Transmitter

MPX OUT -1

Once  the  connection  process  is 
completed, connect the AC power 
to  the  unit. Then,  using  the  front 
panel menu, navigate to

 Input > 

Input  Select  >

  and  set 

Main 

Analog

  input  as  appropriate  for 

your installation.

NOTE: 

It is mandatory (

for both configurations - 

Step 2.1

 and 

Step 2.2

that the cable used for connection 

between DB64

-FM

's MPX output, and the MPX input of the transmitter be as short as possible. This will 

prevent any face distortion. 

Summary of Contents for DB64-FM

Page 1: ...ww devabroadcast com Quick User Guide BEFORE YOU USE THIS PRODUCT In order to be able to enjoy all the benefits of owning your new DEVA product please verify first that the latest software and firmware release were installed Visit www devabroadcast com downloads recent software and firmware downloads prior the installation for the most DEVA Broadcast Limited is an ISO 9001 2008 certified company ...

Page 2: ...device via WEB refer to Step 3 connect the device as an administrator select Presets menu and select the preferred audio preset For further information on how to create your own audio preset or how to set up the Dayprting function please refer to the complete user manual The DB64 FM supports several types of configuration connections depending on the client s preferences The two basic connections ...

Page 3: ...ress Enter 5 A window that requires username and password will appear Default values being Username user or admin Password pass NOTE Due to the inability of some WEB Browsers to read the IP address format displayed on the screen of the device the numbers included in the IP Address must be written without the leading zeros For example 192 168 020 068 must be written as 192 168 20 68 WEB Interface A...

Page 4: ...t network profile 3 Click Turn on network discovery and then click Save changes If you re prompted for an administrator password or confirmation type the password or provide confirmation 4 To access the device open a new Explorer bar and click on If you have successfully enabled the network discovery option the device will be displayed Double click on will open a new WEB browser window requiring u...

Reviews: