65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 33 -
Alarm:
- Range - interactive slider to adjust Low & High Threshold;
- Threshold Low & High - if parameter falls outside this range alarm will be generated.
- Trigger Time - time to wait before Active Alarm is generated;
- Release Time - time to wait before Idle Alarm is generated;
- RDS Group Alarm - check each group of interest. Alarm is generated only for selected
groups.