65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 54 -
HOW TO START A LOGGER CAMPAIGN USING THE FRONT
PANEL MENU?
In order to set up a campaign via the front panel menu, the following steps should be completed:
1. Press the [OK] button to enter the
Main menu> Settings
and again press [OK];
2. Then select
Logger> Channel I
;
3. Specify name of the Channel, frequency and for ‘Active’ - select Antenna 1 or MPX Input;
to exclude a station from the campaign the “Disable” button should be selected;
4. Change the Acquisition time as per your preferences. We recommend setting it to 10 seconds;
5. Change the alarm parameters as per your preferences;
6. Steps from 2 to 4 should be applied for each of the channels to be monitored. Once all PI
Channels are set you can proceed to the last step
7. Go to
Settings> Logger> Logger Mode
and as a value set 10 seconds. In order for a campaign
to be commenced the device should be inactive for the specified time.
NOTE:
The front panel inactivity time should expire prior the Logger mode countdown to
begin.