Error handling
Deutschmann Automation GmbH & Co. KG
40
UNIGATE fieldbus gateway for ProfibusDP V. 4.7
29.4.11
In the configuration mode these displays are not valid and only meant for internal use.
Table 2: Error handling at UNIGATE SC
LED8 LED4 LED2 LED1
Error no.
resp. ID
Error description
0
0
0
0
0
Reserved
0
0
0
1
1
Hardware fault
0
0
1
0
2
EEROM error
0
0
1
1
3
Internal memory error
0
1
0
0
4
Fieldbus hardware fault or wrong fieldbus ID
0
1
0
1
5
Script error
0
1
1
0
6
Reserved
0
1
1
1
7
RS-transmit buffer overflow
1
0
0
0
8
RS-receive buffer overflow
1
0
0
1
9
RS-time out
1
0
1
0
10
General fieldbus error
1
0
1
1
11
Parity- or frame-check-error
1
1
0
0
12
Reserved
1
1
0
1
13
Reserved
1
1
1
0
14
Fieldbus buffer overflow
1
1
1
1
15
Reserved
Summary of Contents for UNIGATE RS232/422