5.7.13
Instruction manual UNIGATE
®
IC - Ethernet V. 2.9
15
Deutschmann Automation GmbH & Co. KG
Hardware design
3.3
Software
The software executes script-commands, which in turn control the IC’s hardware and they pro-
cess their complete protocol by software. The script itself can be generated by the company
Deutschmann Automation or with the software Protocol Developer by yourself. For a detailed
description of the script.commands of the Protocol Developer see the instruction manual Proto-
col Developer and the online documentation concerning script-commands.
3.4
Basic line of proceeding
In theory it is enough to replace the RS232-driver that is included in your application by the UNI-
GATE® IC.
.
. .
. .
. .
. .
Customer
Processor
U
A
R
T
Max 232
9-pol DSUB
RS232
Your device, which on the whole is supposed to be assembled as shown above, will now be mod-
ified in a way that the Ethernet is available at the 9-pol. socket. However, a hardware redesign is
necessary in order to keep the assignment in standard form.
After the RS232-driver has been replaced by the UNIGATE® IC, Ethernet is available at an
RJ45-socket.
Deutschmann Automation is also offering an appropriate adapter board. With it existing devices
can be adapted without re-design; see chapter 13.
3.5
Connection examples
Here you will find some advise that offers help for a re-design. In the following several versions
are listed, that should make it easier for you to decide.