Error handling
Deutschmann Automation GmbH & Co. KG
29
UNIGATE
®
fieldbus gateway UNIGATE
®
EL - DeviceNet
™
V. 1.0
22.6.17
*) The system error 10 is always displayed when one of the following errors appears:
1) Timeout = Expected Packed Rate * 4!
With the Script command "
Get (DetailErrorCode, w_Error)
" the above value can be
read out and with it it can be exactly determined, what error was the actuator.
A detailed error diagnosis can be recorded with an activated "Diagnosis Monitor" via the applica-
tion interface. For this you only need to connect/start a RS232 Monitor tool, such as
Deutschmann Starterkit tool "RS232 module" via a PC. (9600/1/8/N).
An error can be as follows: „(E:21)0x00(ExtErr:030)0x00“.
Note:
"E" shows a script error, the value afterwards in Hex stands for the error number. The error
number can be evaluated in the Protocol Developer Help under Appendix -> Return codes.
"ExtErr:" is for a more detailed fault localization. The script source code can be searched with the
following number (ExtErr:
030
).
Error
Error value
DUP_MAC_ERROR
0x0001
RX_QUEUE_OVERRUN
0x0002
TX_QUEUE_OVERRUN
0x0004
IO_SEND_ERROR
0x0008
CAN_BUS_OFF
0x0010
CAN_OVERRUN
0x0020
EXPL_CNXN_TIMEOUT 1)
0x0040
IO_CNXN_TIMEOUT
0x0080
IO_CNXN_DELETE
0x0100
DNS_RESET
0x0200
DNS_BUS_SENSE_ERROR
0x0400
UNIGATE
®
is turned ON
(START)0x00
IP Adresse at Ethernet port
(EL-IP:172.016.048.203)0x00
Info for internal purposes
(EL-ComChl:00)0x00
State of the 4 Ethernet ports
(EL-State:202010E2)0x00
Ethernet port initialized
(EL-online)0x00
Configured transport protocol
EL-TCP server (port23)0x00
State of the 4 Ethernet ports
(EL-State:202020E2)0x00
Note: is always updated when a state of a channel chan-
ges
State of the Fieldbus ports
(CL-State:000000E0)0x00
State of the 4 Ethernet ports
(EL-State:E32020E2)0x00, (EL-State:212020E2)0x00,
(EL-State:202020E2)0x00, (EL-State:E32020E2)0x00