D-IPS   Manual 

for the power supply 

 
 

1AC:   D-IPS

®

1000C 

3AC:   D-IPS

®

1000/3-C

 

- Controllable Version -

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Important Note: 

Only qualified personnel is allowed to use the device for specified 
application. 
Read the instruction manual carefully and pay attention to the safety 
instructions and manufacturer´s requirements in any case! 

 

Deutronicstrasse 5 
D-84166 Adlkofen / Germany 

Tel.: +49 (0)8707 / 920-199 
Fax: +49 (0)8707 / 1004 

E-Mail: 

[email protected]

 

http://www.deutronic.com 

Summary of Contents for D-IPS 1000/3-C

Page 1: ...d mistakes reserved D IPS Manual for the power supply 1AC D IPS 1000C 3AC D IPS 1000 3 C Controllable Version Important Note Only qualified personnel is allowed to use the device for specified applica...

Page 2: ...unication via digital interfaces RS232 or Ethernet 13 9 a The RS232 interface 13 9 b The Ethernet interface order option 13 10 Command structure description of communication 14 11 Notes 19 12 Annex ac...

Page 3: ...n applied voltage To avoid overheating of the power supply through insufficient convection a miminum distance to the other modules must be maintained 10cm in vertical direction and 2cm in horizontal d...

Page 4: ...on DIN rail mounting Mounting Hang up the device with the DIN rail guide into the top edge of the DIN rail and press down to snap in 1 UP button select parameters 6 DC output 2 ENTER button edit accep...

Page 5: ...st be switchable in volt free mode outside the power supply eg by a breaker or the primary side cable protection The ground conducter has to be connected Recommended minimum cross section of 1 5mm or...

Page 6: ...The controllable power supplies of the D IPS C series have following configuration possibilities Configuration at the device directly via buttons control Configuration of the device via communication...

Page 7: ...orbehalten D IPS and DEUTRONIC are registered trademarks of the Deutronic Elektronik GmbH Technical modificationses and mistakes reserved Description of the LED display Green LED Voltage lead LED ligh...

Page 8: ...urces Internal input Buttons on the unit Analog input 0 10V 4 20mA Digital input RS232 option Ethernet etc 6 a Source input for the voltage by buttons Press ENTER Select with the buttons or Src V in t...

Page 9: ...any button Src V Press the buttons and at the same time to get out of the menu level without overtaking the source Press the buttons and simultaneous once again to get out of the menu then it shows t...

Page 10: ...the configuration of the reference values for the output voltage Reference values for the output current will be adjusted in the same way Press button ENTER for the first menu level The display shows...

Page 11: ...INPUT Programmable input variables OEM maximum input current minimum activation voltage control of power consumption Inhibit start release at phase loss 3AC only Min max start release temperature Min...

Page 12: ...4 20mA Control current current loop 9 ANALOG IN D Current 10 GND 11 MONITOR OUT A 0 10VDC V feedback channel 12 MONITOR OUT B 0 10VDC I feedback channel 13 MONITOR OUT C 4 20mA Current loop V feedback...

Page 13: ...The RS232 interface Pin No Control PC AC DC Source 1 DCD not used 2 RxD TxD 3 TxD RxD 4 DTR not used 5 GND GND 6 DSR not used 7 RTS not used 8 CTS not used 9 RI not used RS 232 interface parameters Ba...

Page 14: ...control of data transmission Control characters Value Start character STX 0x02 End character ETX 0x03 Command mode Extension Example Read Command R OUT UOUTS request voltage reference value Write Com...

Page 15: ...d one or two sub group commands these are connected with Then the marking of the type of the command follows The possible commands are divided into three types READ WRITE EXECUTE The differentiation i...

Page 16: ...turn value ACK Output control OUT UOUT Description Measurement of actual voltage at the output Return value Z OUT UOUTS Description Measurement of nominal voltage for output Return value Z OUT IOUT De...

Page 17: ...e RS232 interface Return value ACK SORV ANL010 Description Switching to the analog input of nominal value for voltage analog input 0 10V Return value ACK SORV ANL040 Description Switching to the analo...

Page 18: ...R DIN2 Description State of digital input 2 Return value SET CLEAR PER DIG1 ON Description State of digital output 1 Subcommand ON OFF Return value ACK Basic setting OFF PER DIG2 ON Description State...

Page 19: ...d DEUTRONIC sind eingetragene Marken der Deutronic Elektronik GmbH Technische nderungen und Irrt mer vorbehalten D IPS and DEUTRONIC are registered trademarks of the Deutronic Elektronik GmbH Technica...

Page 20: ...ion is included The needed return service scripture as well as the world wide service partner addresses you will find on our webpage www deutronic com in the menu item service worldwide Disclaimer The...