14. Never start the water pump before submerge
the appliance into water.
15. This pump is designed for dirty water
with a diameter of suspended impurities
between 5 and 25 mm. Bigger impurities
could damage your pump or block your pipes.
16. Never use the pump where there are people
in the water.
17. This appliance should not be used for drinking
water. Pollution of the liquid could occur due
to leakage of lubricants.
INSTALLATION
This pump is scheduled for installation in
domestic use only:
• In places where there is a risk of flooding.
• In sumps.
Obey free space around the pump for the float
switch can operate without risk of being blocked
(eg use a sump of 40 x 40 x 50 cm minimum). The
pump is scheduled for operation in liquid not
exceeding 35 degrees C.
Before usage, make sure the water evacuated
could be conducted without risks (refer to local
regulations). Do not place the evacuation of
water on a highway or on the passageway.
HOSE CONNECTION
The pump is equipped with an universal fitting
which allows connecting hoses of various sizes as
listed below:
13mm (1/2”)
15mm (5/8”)
19mm (3/4”)
25mm (1”) 32mm (1 ¼”)
3
2
1
a
b
b
a
1. Connection for hoses of diameter 13 / 15 / 19
mm :
• Cut off the topmost nipple on the universal
fitting at position (a).
• Screw a 25,4 mm tap adaptor onto the universal
fitting.
• Connect a hose quick connector (for hose of
diameter 13 / 15 / 19 mm) to the tap adaptor,
the insert the hose and tighten it.
2. connection for hose of diameter 25 mm :
• Screw an push a hose of diameter 25 mm onto
the universal fitting without cutting anything
Tighten the hose with a hose clamp.
3. Connection for hose of diameter 32 mm :
• Cut off top two nipples on the universal fitting
at the position (b).
• Screw and push a hose of diameter 32 mm onto
the universal fitting.
• Tighten the hose with a hose clamp.
Note:
hose, tap adaptor, hose quick connector
and hose clamp are not provided.
OPERATION
The float switch turns the pump on automatically
when the water level exceeds the cut in height
and the water is pumped out.
The float switch turns the pump off again as soon
as the water level falls below the cut- out height.
1. Stand the pump on a firm surface or use a rope
attached through the handle.
2. Ensure that the float switch can move freely.
3. Plug the power cable into a mains socket.
4. Push the cable of the float switch into the float
switch lock Do not select a cable length that
is too long or short to ensure that the float
switch can turn on and off properly. The
cable length between the float switch and the
float switch lock must always be at least 10 cm.
The shorter the length of cable between the
float switch and the float switch lock, the lower
the cut-in height and the higher the cut-out
height. Starting and stopping of the pump
depends on the water level for which the float
switch floats.
Warning:
In order to protect the pump from
running empty, please always keep the pump
upright and the float switch is not jammed in mud
or obstructed by other objects.
Check before entry into service:
• Look to see if there is any damage to the pump
(especially to the power cable and plug).
• The height of the point of switching “on” and
“off” should be easy to achieve.
• Check the operation in a barrel filled with water.
Immerse the pump into water and then slightly
lift and put down the float switch. The pump
starts and stops.
• The float switch should not touch the bottom
before the pump cut off, or there will be a risk
of running empty.
CARE AND MAINTENANCE
Unplug the power cord from the pump before
any maintenance and cleaning.
Check all parts for signs of wear. If any problems
are detected, do not use the product. Always
replace all parts with original replacements
according to the manufacturer’s guidelines.
If the product is not properly cared for and
maintained, it can become unsafe and can also
become damaged. This can lead to dangerous
situations.
Regular maintenance on the product helps to
make the product safe and will also increase its
lifespan.
Use a soft, damp cloth to clean the plastic part.
Do not use detergents, solvents or sharp objects.
Clean and store the pump in a frost-free place
before the first frost arrives.
Disposal:
Once item end-of-life, please dispose valuable
raw materials for a proper recycling. If you are
not sure how to handle it in a correct way please
contact your local disposal or recycling centers
for advice.
Manufactured for:
Deuba GmbH & Co. KG
Saarbrücker Str. 216
66679 Losheim am See
Deutschland
Customer Service:
+49 (0)6861 / 901 00 00
Availability: From Monday to Friday from
10am to 6pm
(price of the call will depend on your phone
contract conditions)
Feel free to contact us by email. kontakt@
deuba.info Our customer service will reply
your enquiry in the next 24 hours (working
days) and in the next 48 hours (on weekends).