Table 3: Airflow tables SUPREME Advantage ECM ½ HP motor
COOLING OR HEAT PUMP HEATING MODE (WITH HP-EFF SELECTED
1
)
CFM
2
CFM
2
CFM
2
AC / HP SIZE
A/C size AC/HP CFM ADJUST AC/HP CFM ADJUST
AC/HP CFM ADJUST
Adjustment
(TONS)
BLACK wire position
BLACK wire position
BLACK wire position
BLUE wire position
(BLK) = (NOM)
(BLK) = (LO)
(BLK) = (HI)
36
3,0
1200
1080
1320
30
2,5
1000
900
1100
24
2,0
800
720
880
18
1,5
600
540
660
1
"SYSTEM TYPE"
2
In Cooling - Dehumidification mode (with Jumper
J1
remove), with no 24 VAC input to DH, the CFMs are
reduced by 15%.
The CFMs shown are reduced by 20% if there is 24VAC input to Y1 only (Y/Y2 not powered)
CONTINUOUS FAN
CFM
1
CFM
1
CFM
1
AC / HP SIZE
A/C size
CONTINUOUS FAN
CONTINUOUS FAN
CONTINUOUS FAN
Selection
(TONS) YELLOW wire position YELLOW wire position
YELLOW wire position
BLUE wire position
(YEL) = (LO)
(YEL) = (MED)
(YEL) = (HI)
36
3,0
600
960
1200
30
2,5
500
800
1000
24
2,0
400
640
800
18
1,5
300
480
600
1
PCM quand AC/HP CFM ADJUST est à la position NOM. PCM inférieur ou supérieur de 10% si AC/HP
CFM ADJUST est à la position LO ou HI.
ELECTRIC HEATING MODE
CFM
HEAT KW/CFM
POWER
CFM
Second stage
adjustment
(kW)
First Stage
24VAC on W1
RED wire position
24 VAC on W1
1
and/or W2
1
25
25
715
1359
23/20
23
620
1178
23/20
20
620
1178
18/15
18
450
855
18/15
15
450
855
10
10
238
452
1
Remove the Jumper
J2
when a 2 stages thermostat is used
16